Service manual
www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual
151
F5.02 Input terminal X3 function selection 0 12
F5.10
Open circuit collector output terminal OCI
Output setting
0 2
F5.15 FDT1(frequency level )electric level 2.60Hz 2.60Hz
F5.16 FDT1 lag 0.01Hz 0.01Hz
F7.03 VCI max provision corresponding freq. 50.00 75.00
7.1 parameters setting reference of fine-drawing machine and
micro-pulling machine
7.1.1 Host parameters of fine-drawing machine and micro-pulling machine
(EDS1000 Series)
Function Code Function Name Factory Value Setting
F0.00 Frequency input channel selection 1 4
F0.02 Run command channel selection 0 1
F0.08 Acceleration time 1 20.0 40.0-60.0
F0.09 Deceleration time 1 20.0 40.0-60.0
F0.10 Upper limit Frequency 50.00Hz 80.00
F0.14 Torque boost 0.5 2.5
F2.06 Jog run frequency 5.00Hz 6.00
F2.07 Jog acceleration time 20.0s 6.0
F2.08 Jog deceleration time 20.0s 6.0
F3.30 Failure relayTA,TB, TCfunction selection 15 15
F5.00 Input terminal X1 function selection 0 11
F5.01 Input terminal X2 function selection 0 5
F5.02 Input terminal X3 function selection 0 12
F5.10
Open circuit collector output terminal OCI
output setting
0 2
F5.15 FDT1(frequency level)electric level 10.00Hz 5.50
F5.16 FDT1 lag 1.00Hz 0.01
F5.17 Analog output (AO1)selection 0 0
F5.18 Analog output (AO1)gain 1.00 1.00
F5.19 Analog output (AO1)offset 0.00 0.00
F5.20 Analog output (AO2) selection 0 0
F5.21 Analog output (AO2) gain 1.00 1.00
F5.22 Analog output (AO2) offset 0.00 0.00
F7.03 VCI max. provision corresponding freq. 50.00 80.00