www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual
145
F3.30
Failure relay
TA,TB,TC
function selection
0:inverter running(RUN)
1:frequency arriving signal(FAR)
2:frequency level detecting signal(FDT1)
3:reserved
4:Over load warning alarm signal(OL)
5:Output frequency reach high limit
(FHL)
6:Output frequency reach low limit(FLL)
7:inverter under voltage blockage stop (LU)
8:external failure stop running (EXT)
9: inverter zero speed running
10:PLC running
11:simple PLC section running finished
12:PLC finish a cycle running
13:reserved
14:inverter ready to run (RDY)
15:inverter malfunction
16:Swing frequency high and low limit
restriction
17:interior counter reach final value
18:interior counter reach specified value
19:set run time arriving
20:interior timing arriving
21:reserved
22:reserved
23:
reserved
24:reserved
15 ○
F5-Terminal correlative function parameter group
Function
code
Name Set range Unit
Factory
default
Modifica
tion
F5.00
Input terminal X1 function
selection
31:Run command channel selection 3
32:Swing frequency jump-in
33:External interruption input
34: Interior counter reset end
35:Interior counter triggering end
36:Interior timer reset end
37:Interior timer triggering end
38:Pulse frequency input(Only effective for
X7,X8)
39:Reserved
40:Reserved
41:Reserved
42:Reserved
1 0 ×
F5.01
Input terminal X2 function
selection
Same as above
F5.02
Input terminal X3 function
selection
Same as above