Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual
143
F1Start-up, stop, brake function parameter group
Function
code
Name Set range Unit
Factory
default
Modificat
ion
F1.05 Stop mode
0Deceleration stop
1free stop
2DecelerationDC brake stop
1 0 ×
F1.06
DC brake initiative freq.
when stop running
0.015.00Hz 0.01Hz 0.00Hz
F1.07
DC brake time when stop
running
0.020.0s 0.1s 0.0s
F1.08
DC brake voltage when stop
running
015(%) 1 0
F2Auxiliary run function parameter group
Function
code
Name Set range Unit
Factory
default
Modific
ation
F2.00 Analog filter time constant 0.0030.00s 0.01s 0.20s
F2.06 Jog run frequency 0.1050.00Hz 0.01Hz 5.00Hz
F2.07 Jog acceleration time 0.160.0s 0.1s 20.0s
F2.08 Jog deceleration time 0.160.0s 0.1s 20.0s
F2.18
Acce.time2(Smoothly start-up
Acce.time)
0.16000.0 0.1 20.0
F2.19
Dece.time 2(Smoothly start-up
Dece.time)
0.16000.0 0.1 20.0
F2.21
Interval time 1 of retracting volume
diameter calculation
0~500ms 1ms 300ms
F2.22
Empty diameter gain(retracting and
releasing gain)
0.0~800.0% 0.1% 40.0
F2.23 PID adjustor gain 0.0~800.0% 0.0% 30.0
F2.24
Start-up volume diameter calculation
gain selection
0F2.25
1F2.26
1 0
F2.25
Start-up volume diameter calculation
gain( volume diameter calculation gain
4)
0.0~20.0% 0.1% 0.8
F2.26 Volume diameter calculation gain 3 0.0~20.0% 0.1% 0.4
F2.27 Volume diameter calculation gain 2 0.0~20.0% 0.1% 0.0
F2.28 Volume diameter calculation gain 1 0.0~20.0% 0.1% 0.0
F2.29 Upper limit of retracting volume gain 0.0~200.0% 0.1% 100.0
F2.30
Start-up retracting and releasing gain
control
0calculation
1with out change
1 1
F2.31
Retracting and releasing speed gain +/-
control
00~F2.30
1-F2.30~F2.30
1 0
F2.32
Retracting and releasing recombination
control
0externally input
1interiorly input
1 0
F2.33
Interval time 0 of retracting volume
diameter calculation
0~500ms 1 800
F2.34
Dead zone of of retracting volume
diameter calculation
0.01~1.00V 0.01V 0.10