Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual
142
Vibration Smaller than 5.9m/s2(0.6g)
Storage tempera ion -40ºC~+70ºC
Defending grade IP20
Cooling mode
Compel wind coolingBy fan with automatic temperature
control
Mounting mode Wall hanging
4.1 Function code schedule graph
4.1.1 Function code schedule graph especially for drawing machine
Telecommunication serial No. is the function code address when computer
communicates.
F0Basic run function parameter group
Function
code
Name Parameter setting Unit
Factory
default
Modificati
on
F0.00
Frequency input
channel selection
0keyboard analog potentiometer setting
1operation keyboard digital setting
2terminal UP/DOWN adjust setting frequency(stored
after power off)
3Serial port setting
4VCI analog settingVCI-GND
5CCI analog settingCCI-GND
6YCI analog settingYCI-GND
7terminal pulsePULSEfrequency setting
8combination setting
9 terminal UP/DOWN adjust setting frequency(not
stored after power off)
1 0
F0.02
Run command
channel selection
0operation keyboard run control
1terminal run command control(keypad STOP
command ineffective )
2terminal run command control(keypad STOP
command effective )
3serial port run command control ((keypad STOP
command ineffective)
4serial port run command control ((keypad STOP
command effective)
1 0
F0.03
Run direction
setting
Unit’s digit0forward run, 1reverse run
Tens place0reverse run allowed
1reverse run banned
1 00
F0.08 Acce. time 1 0.16000.0 0.1 20.0
F0.09 Dece. time 1 0.16000.0 0.1 20.0
F0.10 Upper limit freq. Lower limit freq.400.00Hz 0.01Hz 50.00Hz ×
F0.14 Torque boost 0.020.0(%) 0.1(%) 2.0(%)