www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual
142
Vibration Smaller than 5.9m/s2(0.6g)
Storage tempera ion -40ºC~+70ºC
Defending grade IP20
Cooling mode
Compel wind cooling,By fan with automatic temperature
control
Mounting mode Wall hanging
4.1 Function code schedule graph
4.1.1 Function code schedule graph especially for drawing machine
Telecommunication serial No. is the function code address when computer
communicates.
F0-Basic run function parameter group
Function
code
Name Parameter setting Unit
Factory
default
Modificati
on
F0.00
Frequency input
channel selection
0:keyboard analog potentiometer setting
1:operation keyboard digital setting
2:terminal UP/DOWN adjust setting frequency(stored
after power off)
3:Serial port setting
4:VCI analog setting(VCI-GND)
5:CCI analog setting(CCI-GND)
6:YCI analog setting(YCI-GND)
7:terminal pulse(PULSE)frequency setting
8:combination setting
9: terminal UP/DOWN adjust setting frequency(not
stored after power off)
1 0 〇
F0.02
Run command
channel selection
0:operation keyboard run control
1:terminal run command control(keypad STOP
command ineffective )
2:terminal run command control(keypad STOP
command effective )
3:serial port run command control ((keypad STOP
command ineffective)
4:serial port run command control ((keypad STOP
command effective)
1 0 〇
F0.03
Run direction
setting
Unit’s digit:0:forward run, 1:reverse run
Tens place:0:reverse run allowed
1:reverse run banned
1 00 ○
F0.08 Acce. time 1 0.1-6000.0 0.1 20.0 ○
F0.09 Dece. time 1 0.1-6000.0 0.1 20.0 ○
F0.10 Upper limit freq. Lower limit freq.-400.00Hz 0.01Hz 50.00Hz ×
F0.14 Torque boost 0.0-20.0(%) 0.1(%) 2.0(%) ○