10.2 Terminal control running
10.2.1 Basic wiring diagram
Fig.10-2
10.2.2 Parameter setting
(1) Set parameter F8.01-F8.06 according to rated value of the motor.
(2) Set F0.00 parameter to 4~6 to choose VCI, CCI, YCI accordingly, can accept
frequency set signal within 0~10V.
(3) Set F0.02 parameter to 1,to choose terminal run command channel.
10.2.3 Realized function
(1) control forward run/reverse run of the motor by external on-off quantum.
(2) control speed of the motor by 0~10V signal.
(3) bear failure warning and output current indication function.
10.2.4 Application field
Used in field where need long-distance control to start/stop of the motor such as
blower, food, chemical machine, packing machine, transportation machine etc.
S
T
FWD
COM
TA
TC
M
U
E
motor
W
V
TB
REV
VCI
GND
AO1
GND
R
3 phase breaker
3 phase 380V
50/60Hz
forward run
reverse run
specified signal 10K
10V/5V
L1
L2
failure warning light
ammete
r
EDS1000
(1) If F5.08=0,namely 2 wire control mode 1: FWD and COM are closed,moter is
in forward run;REV and COM are closed,motor is in reverse run;FWD, REV
and COM are closed or opened together,the inverter stop.
(2) Set frequency is specified through VCI analog channel.
note