Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 10 Examples
117
10 Examples
10.1 Common speed regulation running
10.1.1 Basic wiring diagram
Fig.10-1
10.1.2 Set following basic parameter:
(1) set parameter F8.01-F8.06 according to rated value of the motor.
(2) set F0.00 parameter to 0choose keypad analog potentiometer to set frequency.
(3) set F0.02 parameter to 0choose keypad to control start-up, stop.
(4) use F0.03 parameter to set run direction.
10.1.3 Realized function
(1) Realize stepless speed regulation to the motor, use keypad to control start/stop
and keypad analog potentiometer to adjust frequency.
(2) Bear failure warning function.
(3) Connect with cymometerwhich indicates output frequency of the inverter.
10.1.4 Application field
Used for common speed regulation fieldsuch as: transportation machine, china
machine, baccy machine, metallurgy machine etc.
ENTER
D
ATA
3 phase breaker
3
p
hase
p
ower su
pp
l
y
R
S
T
TA
TB
TC
AO1
M
U
V
W
E
moto
r
L1
L2
failure waring light
GND
cymomete
r
EDS1000
(1) Press key to set frequency.
(2) To press keythe inverter will stop.
(3) To press keyinverter enter into next menu or confirm data.
(4) Press key to increase or decrease the data.
note
STOP
RESET
ENTER
DATA