Service manual
www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 6 Detailed function description
109
0: no failure
1―23: failure E0.01-E0.23,please see chapter 7 for specified failure type
Fd.06
Set freq. at previous failure Range: 0-high limit 0
Fd.07
Output freq. at previous failure
Range: 0-high limit 0
Fd.08 Output current at previous failure Range: 0-999.9A 0
Fd.09 Output volt. at previous failure Range: 0-999V 0
Fd.10 DC bus-bar volt. at previous failure Range: 0~800V 0
Fd.11 Load motor speed at previous failure Range: 0~9999 0
Fd.12 Module temp. at previous failure Range: 0~100 0
Fd.13 Input end state at previous failure 11111111
Fd.14 Accu. runtime at previous failure Range: 0~65535h 0
6.12 Password and manufacturer function parameter group: FF
FF.00 User password Range: 0000-9999 0000
User password setting function is used for prohibiting unauthorized personnel
from consulting and modifying function parameter.
Set this function code to 0000 when user password function isn’t wanted.
First input 4 bits number as user password and press key to confirm,
then the password will come into effect at once.
Password modification:
Enter into password verification state by pressing key, after inputting
primary 4 bits password parameter editing state is available,choose FF.00(here
FF.00=0000),input new password and press key to confirm,then the
password come into effect at once.
FF.01 Manufacturer password
Range: 0000-9999
0000
Setting function for the manufacturer, user need not modify it.
ENTER
DATA
ESC
MENU
ENTER
DATA
Please keep the password you set without fail, in case the password is missing please
consult the manufacturer.
note