Product Specs
4
Minimum
value
Maximum
VCC:Power Supply OUT:Output Signal GND:Ground CDS:photo transistor
Dimension & Pin Assignment
EasyDetek·Focus on Radar
Sensors
Bottom View Unit:mm
Top View Unit:mm
Attentions
Avoid installing together with metal accessories or shell,when install microwave motion
sensor,metal will absorb microwave and affect the effect. Avoid large current circuit cover of
the antenna surface, which may lead to interference.
Please use power supply circuit with tiny ripple current, especially the low frequency ripple,
which disturb the sensor's work easily.The recommend filter E-cap more than 100uF
The output current of the sensor is very weak, If driver too large current easy to cause
misinformation. Better us drive the load by isolation drive, and can also use MCU to read the
output state.
The recommended installation space of sensors is more than 1.5m