6. The RED LED turns on when your radio is sending the Call Alert.
7. If the Call Alert acknowledgement is received, a tone sounds and the display shows Call Alert Successful.
OR
If the Call Alert acknowledgement is not received, a tone sounds and the display shows Call Alert Failed.
▲ Emergency Operation
An Emergency Alarm is used to indicate a critical situation. You are able to initiate an Emergency at any time on any
screen display even when there is activity on the current channel.
Your radio supports 3 Emergency Alarms:
• Emergency Alarm
• Emergency Alarm with Call
• Emergency Alarm with Voice to Follow
In addition, each alarm has the following types:
• Regular —Radio transmits an alarm signal and shows audio and/or visual indicators.
• Silent - Radio transmits an alarm signal without any audio or visual indicators. There will be no response (call) from
the target radio until you press the PTT button to initiate the call.
• Silent with Voice —Radio transmits an alarm signal and is able to receive an incoming call without any audio or visual
indicators until you press the PTT button to initiate or respond to the call.
Only ONE of the Emergency Alarms above can be assigned to the programmed Emergency button.
□ Receiving an Emergency Alarm
Procedure:
1. When receiving an Emergency Alarm, the display shows the Emergency icon, the number of alarms received, and
Alarm Rcvd, which alternates with alias ID of the sender.
2. A tone sounds.
3. If enabled, your radio automatically acknowledges the Emergency Alarm.
When your radio receives an Emergency Alarm, it displays the Emergency Alarm received indications until
acknowledgement is sent and you exit the Emergency mode.