1. Product packaging and accessories:
L001-c charging base 1PCS temperature probe 1PCS type-c USB cable 1PCS
instruction 1pcs carton packaging.
2. The smart device APP shows:
1. APPle app: apple store: AICOOKING
2. Android APP :google Store: AICOOKING
1) When installing the APP, please pay attention to allowing the software to obtain
the positioning function to ensure smooth connection. (This product is a pure
stand-alone machine with no networking function, and all data are stored locally by
customers, and our company does not store any data. )
2) Before using the relay, the APP needs to choose the relay mode, which is the direct
connection mode by default. After selecting the relay mode, the relay will directly
connect the probe Bluetooth to receive data and directly transmit it to the mobile
APP for display, but the probe can't directly connect to the mobile APP. If there is
little interference, the APP can directly choose to switch to the direct connection
mode. The probe can only be connected to one intelligent device, but after
connecting the intelligent device, it can't be connected to the relay device at the
same time. The probe can be turned off temporarily by charging function to cut off
the connection with the APP. Or close the APP or turn off bluetooth to disconnect.
3) The product has no manual shutdown function. The product automatically shuts
down when charging, turns on after disconnecting the charging, and automatically
shuts down when the power is used up. The product has its own charging protection
function, and the product can be stuck into the charging base for a long time to keep
charging. After 20 minutes of capacitor charging, the intelligent charging system will
automatically cut off the charging circuit and keep the product off.
4) After opening the APP, after turning on the positioning and Bluetooth functions,
take off the temperature measuring probe from the base, and the product will
automatically connect to the APP. If it has not been connected for a long time, the
APP has a manual connection function. Please refer to the product manual for
details.
5) The highest temperature resistance of the product temperature measuring area is
140 degrees Celsius. After the temperature exceeds 140 degrees Celsius, the
temperature measuring area must be inserted into food before it can be put into the
high temperature area (see the figure below for the correct insertion of the product
into food), and the highest temperature resistance of the product is 300 degrees
Celsius.
6) After choosing a good recipe, the APP will have an estimated completion time