Specifications
深圳市创荣发电子有限公司
SHENZHEN C&D ELECTRONICS CO., LTD.
Page 14/42
reaches the stable laboratory environment temperature, take out the remote controller and check
whether the functions of the remote controller are normal.
5.2
恒定湿热试验
Constant temperatu
re and humidity test
遥控器在不包装不装电池的状态下,放入具有室温的试验箱内,然后将箱温调节至 40±2℃,当遥控器达
到温度稳定后再加湿度在相对湿度为 93%,搁置 96H,先把试验箱内的相对湿度在 0.5h 内降低到
75%±3%,然后在 0.5H 内把试验箱内的温度调到正常试验大气条件下,取出遥控器 。遥控器恢复 4H
后,检查遥控器的各项功能是否正常.Remote control under the conditions of the packing is not install
batteries, in a room temperature test box, then put the box temperature adjusting to 40 + 2 ℃, after
reaching a stable temperature and humidity when the remote control to the relative humidity is 93%,
put aside 96 h, the test of the relative humidity in the first cut to 75% within 0.5 h + / - 3%, then within
0.5 h to test the temperature in the cabinet to atmospheric conditions, normal test out the remote
control. After the remote control is restored for 4 hours, check whether the functions of the remote
control are normal.
5.3
High temperature
storage test
高温储存测试
Expose to a constant temperature and humidity of 60±2℃ for 96h without load.
把遥控器暴露在恒温恒湿 60±2℃的环境中 96 小时,不带任何负重。
Perform measurements after leaving at normal
temperature and humidity for 1h.
取出遥控器放在常温状态中静置 1 小时。
->The RCU SHOULD operate normally.
遥控器正常工作
5.4
Low temperature
storage test
低温储存测试
Leave RCU under the condition; -20℃ for 96 hours, and leave it under standard condition for 1 hour,
and test the performance.
把遥控器放在如下的条件中: -20℃ 96 小时,然后取出放到常温状态下 1 小时,然后测试遥控器功
能。
->The RCU SHOULD operate normally.
遥控器正常工作
5.5
高低温操作和潮态耐受
High and low
temperature operation
and tide tolerance test
遥控器在装电池的状态下:Remote control with battery:
1.温箱室温下降到-10℃,保持 5 小时(在 3 小时左右拿出遥控器迅速进行功能检查、以及触控部分的
灵敏度、反应速度检查)Drop the temperature of the temperature box to -10℃ and keep it for 5 hours
(about 3 hours, take out the remote control and quickly check the function, as well as the sensitivity
and reaction speed of the touch control part)
2.低温状态下马上拿到 25℃,80%湿度环境,3 分钟内表面结露状态下进行测试; At low temperature,
25℃ was immediately obtained, 80% humidity was obtained, and the surface was dewy within 3
minutes for testing;
3.上升温度到零上 45 度,60%湿度(温度保持 3 小时左右同样检查遥控器功能、按键手感以及触控部