Specifications
深圳市创荣发电子有限公司
SHENZHEN C&D ELECTRONICS CO., LTD.
Page 12/42
共 6 小时)
*测试后,在室温中放置 30 分钟,然后检
查外观和电气性能. after testing, leave it at room
temperature for 30 minutes, then check
appearance and electrical properties.
4.26
包装运输试验:跌落
试验 Packing and
transportation
test: drop test
没有功能失效或材料损坏 No functional failure
or material damage
将整箱产品从 60cm 高度跌落到地面,对其中三
个轴向,1 边和 1 个角进行试验. FCL products
were dropped from a height of 60cm to the
ground, and three axial directions, one side
and one Angle were tested.
4.27
Key strength or
Key over load test
按键抗压 测试
Please change to "Add a vertical load(50N)
to a key top for 5 seconds".
在按键上增加一个 50N 的垂直力,持续 5S,
遥控器的壳子和内部元器件不可以裂缝和破损
Add a vertical load(50N) to a key top for 5
seconds
->A case and inside parts SHOULD not be
cracked and broken
在按键上增加一个 50N 的垂直力,持续 5S.
4.28
抗扭强度 Torsional
strength test.
无机壳爆开,无"嗞嗞"声,无机械损伤,功能正
常。No housing burst, no "sizzle", no
mechanical damage, function normal.
以 5N 的力矩扭机身 1000 次. Twist the
remote control 1000 times with 5N torque.
4.29
Electrostatic
destruction test
静电破坏测试
(1)Discharge electricity to the joint between Upper
case and Lower case.
对着上壳和下壳之间的缝隙进行放电
(2)Discharge electricity to the terminal in a battery
box.
在电池仓的两端进行放电
*Probe Condition: C=200pF/R=100Ω->150pF/330
Ω
针头条件:C=200pF/R=100Ω->150pF/330Ω
->The product SHOULD not be damaged.
产品不能损坏
>from 1kV to specified voltage raising 1kV step
从 1KV 做为起点,1KV 1KV 的往上增加,直到要
求的电压值
>each voltage shall be discharged 10 times 每个电压
值下放电 10 次
>Dis-electrify RCU after each discharge 每次放电后
等静电干净后
[ Air discharge SPEC ]空气放电
MALFUNCTION(故障) ±15kV
DESTRUCTION(摧毁)±18kV
*Test with the battery inserted 装上电池测试
[ Contavt discharge SPEC (Battery Terminals)]
接触放电规格(电池两端)
MALFUNCTION(故障) ±5kV
DESTRUCTION(摧毁)±5kV