User Manual LCD DISPLAY MDA2120-A/MDA2120-S
MDA2120-A/MDA2120-S User Manual Content 1. 2. SAFETY SYMBOLS & PRECAUTIONS ........................................................................................................ 3 1.1 SAFETY SYMBOLS ......................................................................................................................................... 3 1.2 PRECAUTIONS................................................................................................................................................
MDA2120-A/MDA2120-S User Manual 1. Safety Symbols & Precautions 1.1 Safety Symbols This manual uses below safety symbols. They denote critical information. Please read them carefully. WARNING Failure to abide by the information in a WARNING may result in serious injury and can be life threatening. CAUTION Failure to abide by the information in a CAUTION may result in moderate injury and/or property or product damage. Alert electrical hazard. Indicates a prohibited action. Indicates to ground for safety.
MDA2120-A/MDA2120-S User Manual Set up the unit in an appropriate location. Not doing so may result in fire, electric shock, or equipment damage. - Do not place the unit outdoors. - Do not install the unit in transportation systems (ship, aircraft, trains, automobiles, etc.) - Do not place the unit in a dusty or humid environment. - Do not place the unit in a location where the steam comes directly on the screen. - Do not place the unit near heat generating devices or a humidifier.
MDA2120-A/MDA2120-S User Manual CAUTION Handle with care when carrying the unit. Disconnect the power cord and signal cables and remove the optional unit. Moving the unit with the cord or the option attached is dangerous. It may result in injury. When handling the unit, grip the bottom of the unit firmly with both hands ensuring the panel faces outward before lifting. Dropping the unit may result in injury or equipment damage. Do not block the ventilation slots on the cabinet.
MDA2120-A/MDA2120-S User Manual 2. Introduction Thank you for purchasing the latest ARMSTEL Amedicom® model of dual-mode medical LCD monitor. ARMSTEL Amedicom® MDA2120-A and MDA2120-S 2MP color dual-mode medical LCD displays, with high resolution 1600x1200, are intended to be used in displaying and viewing digital images, for medical diagnostic reviewing and analysis by trained medical practitioners. Each monitor has been precisely calibrated to comply with DICOM Part 14 GSDF standard at factory.
MDA2120-A/MDA2120-S User Manual 2.1. OSD and Interface a. Front b.
MDA2120-A/MDA2120-S User Manual 3. Quick start 1.Cable Connection Connect all cables to the appropriate connectors, as shown in below picture. 2.Adjust the height, position and angle of monitor. Screen Rotation Before rotating, the screen must be raised to the highest level to avoid knocking the screen on the desk or pinching with your fingers.
MDA2120-A/MDA2120-S User Manual 3.Turn on the monitor, the power indicator light will become green. Start the computer and set mode of monitor as below: 1200 x 1600 (in portrait mode) or 1600 x 1200 (in landscape mode). NOTE: If no picture, please refer to the Troubleshooting section of this manual. The original screen deflection, turn on the video card control interface, alter the rotation angle to the required display effect.
MDA2120-A/MDA2120-S User Manual 4. Adjustment This monitor will not likely require adjustment. Variations in video output and application may require adjustments to the monitor to optimize the quality of the display. For best performance, the monitor should be operating in native resolution 1600x1200. Use the Display control panel in Windows to choose 1600x1200 resolution. Operating in other resolutions will degrade video performance. All control adjustments are automatically memorized.
MDA2120-A/MDA2120-S User Manual Use the Control buttons to make all required adjustments and press the MENU button to save the settings. 4.Exiting the OSD MENU To return to the main menu, select the icon and press the MENU button. To exit the OSD menu, select icon. 4.
MDA2120-A/MDA2120-S User Manual Red/Green/Blue color adjustment: use to adjust the value of red, green and blue to change the image color so as to meet your needs. Color temperature: use to select desired color temperature (9300k, 6500k,U SER) Color adjustment: it can be adjusted if under shadow mode. If you are not satisfied with the color temperature set by manufacturer, you may set the color temperature to USER mode; it will light red at this time.
MDA2120-A/MDA2120-S User Manual Select terminal input: select input terminal for signal input(option) Exit: exit OSD menu 4.3 DICOM GSDF Calibration The ARMSTEL Amedicom® MDA2120-A medical dual-mode display has the built-in calibrated DICOM GSDF compliant BARTEN curve for medical image display, with patented (pending) ARMSATTTM technology embedded. It also allows user to push single “CAL” button to do the automatic backlight adjustment and calibration.
MDA2120-A/MDA2120-S User Manual ® 5) Double click to run ARMSTEL Amedicom CalispectorTM software installed above. Note, during the calibration, make sure that SimluxTM meter is sitting in the middle of the CalispectorTM operating window, and the window should be sufficiently big to cover the whole meter during the whole calibration process for the accurate calibration; For the use of CalispectorTM, please refer to ARMSTEL home page for CalispectorTM User Manual.
MDA2120-A/MDA2120-S User Manual 7.
MDA2120-A/MDA2120-S User Manual 8. Specification 8.1 Specification Panel: 20.1″ active display Supported Color : 16,777,216 colors Native resolution: 1600 x 1200 Pixel pitch: 0.255 x 0.255 mm Brightness: 300cd/m2 Typ. Contrast ratio: 800:1. Response time: 14 ms Typ. Connections: DVI-D D-Sub Operating temperature: Storage temperature: Relative humidity: Certification: 0° to 40°C -20° to 65°C 5% to 90%, non condensing CCC,CE,FCC 8.
MDA2120-A/MDA2120-S User Manual 8.3 DVI-D Connector Pin# Signal Pin# 1 T.M.D.S Data2- 11 2 T.M.D.S Data2+ 12 3 T.M.D.S Data2/4 Shield Signal Pin# Signal 21 NC NC 22 T.M.D.S Clock Shield 13 NC 23 T.M.D.S Clock+ T.M.D.S Data1/3 Shield 4 NC 14 DDC +5V 24 T.M.D.S Clock- 5 NC 15 GND C1 NC 16 HPD C2 NC 17 T.M.D.S Data0- C3 NC 6 7 DDC-Serial Clock(SCL) DDC-Serial Data(SDA) 8 NC 18 T.M.D.S Data0+ C4 NC 9 T.M.D.S Data1- 19 C5 NC 10 T.M.D.S Data1+ 20 T.M.
FCC Warning: z This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: z (1) this device may not cause harmful interference, and z (2) this device must accept any interference received, including interference that may cause undesired operation. z Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
ARMSTEL, Inc. 888 S. Greenville Ave. Suite 103, Richardson, TX U.S.A. 75081 Tel: +001 972-231-8793 Website: www.armstel.