User Manual 3MP Color LCD Display C32SP+/C32S+ Rev.
C32SP+/C32S+ User Manual Content 1. SAFETY SYMBOLS & PRECAUTIONS ...........................................................................................................- 3 1.1 SAFETY SYMBOLS ............................................................................................................................................ - 3 - 1.2 PRECAUTIONS...................................................................................................................................................
C32SP+/C32S+ User Manual 1. Safety Symbols & Precautions 1.1 Safety Symbols This manual uses below safety symbols. They denote critical information. Please read them carefully. WARNING Failure to abide by the information in a WARNING may result in serious injury and can be life threatening. CAUTION Failure to abide by the information in a CAUTION may result in moderate injury and/or property or product damage. Alert electrical hazard. Indicates a prohibited action. Indicates to ground for safety.
C32SP+/C32S+ User Manual Set up the unit in an appropriate location. Not doing so may result in fire, electric shock, or equipment damage. - Do not place the unit outdoors. - Do not install the unit in transportation systems (ship, aircraft, trains, automobiles, etc.) - Do not place the unit in a dusty or humid environment. - Do not place the unit in a location where the steam comes directly on the screen. - Do not place the unit near heat generating devices or a humidifier.
C32SP+/C32S+ User Manual CAUTION Handle with care when carrying the unit. Disconnect the power cord and signal cables and remove the optional unit. Moving the unit with the cord or the option attached is dangerous. It may result in injury. When handling the unit, grip the bottom of the unit firmly with both hands ensuring the panel faces outward before lifting. Dropping the unit may result in injury or equipment damage. Do not block the ventilation slots on the cabinet.
C32SP+/C32S+ User Manual 2. Introduction C32SP+/C32S+ 3MP Color LCD display, with high resolution 2048x1536, is intended to be used in displaying and viewing digital images, for review and analysis by trained medical practitioners. Each monitor has been precisely calibrated to comply with DICOM Part 14 at factory. With built-in brightness stabilization circuit, front sensor and ambient light sensor, stable brightness and persistent calibration can be guaranteed.
C32SP+/C32S+ User Manual 3. Quick start Note: turn off the power to your computer and monitor. 1. Cable Connection Connect all cables to the appropriate connectors, as shown in below picture. 2. Adjust the height, position and angle of monitor. Screen Rotation Before rotating, the screen must be raised to the highest level to avoid knocking the screen on the desk or pinching with your fingers.
C32SP+/C32S+ User Manual 3. Turn on the monitor, the power indicator light will become green. Start the computer and set mode of monitor as below: 1536 x 2048 (in portrait mode) or 2048 x 1536 (in landscape mode). NOTE: If no picture, please refer to the Troubleshooting section of this manual. The original screen deflection,turn on the video card control interface, alter the rotation angle to the required display effect.
C32SP+/C32S+ User Manual 4. Adjustment LED indicator LED Color The status of the monitor Green.
C32SP+/C32S+ User Manual 5. OSD MENU Main Menu Input Function Option Description Select Brightness DP DVI 0-100 Contrast 0-100 Adjust Contrast Gamma DICOM DSA DSI CT MRI 2.2 2.0 1.8 >>> Select Gamma Curve Full Screen Native English 中文 Center Bottom OFF/90/ 180/270 Select Aspect Ratio Input Image Color Temp. Aspect Ratio Language OSD Position OSD Rotation Setup Status Input source Adjust black level Go to Color Temp.
C32SP+/C32S+ User Manual 6. Trouble Shooting If a problem persists even after applying the suggested remedies, contact a dealer. Problems 1. No picture Indicator status: Off Points to check with Possible Solutions Check if the power cord is correctly connected. If the problem persists, turn off the monitor for a few minutes, then turn it on and try again. Indicator status: Orange Press the keyboard of computer or click the mouse, turn off the monitor and then restart. 2.
C32SP+/C32S+ User Manual 7. Cleaning Periodic cleaning is recommended to keep the monitor clean and to prolong its operation lifetime. Note: Never use thinner, benzene, alcohol (ethanol, methanol, or isopropyl alcohol), abrasive cleaners, or other strong solvents, as these may cause damage to the cabinet or LCD panel. Cabinet To remove stains, wipe the cabinet with a soft, lightly moistened cloth using a mild detergent. Do not spray wax or cleaner directly into the cabinet.
C32SP+/C32S+ User Manual 8.
C32SP+/C32S+ User Manual 9. Specification 9.1. Specification Panel 21.3”, TFT Color LCD screen, antigalre Brightness (typ.) 800 cd/m2 CR (typ.) 1400:1 Viewing angle R/L 176° ,U/D 176° Pixel Pitch 0.2115 mm Native resolution 2048 x1536 Display area 433.152mm (H) x 324.864 mm (V) Power DC12V/10A Power consumption MAX.
C32SP+/C32S+ User Manual 10. FCC Statement: z This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. z This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
C32SP+/C32S+ User Manual Shenzhen Beacon Display Technology Co.,Ltd Room 201, Incubator Building, CASTD, High-tech South 1st Street, Nanshan District, Shenzhen Tel: +86 755 26050699 26995355 Fax: +86 755 26995755 Website: www.beacon-display.