Arm Blood Pressure Monitor User Manual Model:AOJ-30C
Table of Contents 1. Unpacking Inspection ........................................................... 1 2. Packing List ......................................................................... 1 3. Safety Precautions and Warnings ........................................ 2 4. Product Composition............................................................ 5 5. Intended Use / Instructions for Use ....................................... 5 6. Contraindication ....................................................
Thank you for purchasing this Arm Blood Pressure Monitor. The monitor can be used and store measurement results for two users. It uses the oscillometric method of blood pressure measurement. This means this monitor detects your blood movement through your brachial artery and converts the movements into a digital reading. The device can be used in homecare environment, and the patient is an intended operator, and all the functions can be safely used. 1.
3. Safety Precautions and Warnings • No maintenance or servicing the monitor when using. • The patient is an intended operator, and all the functions can be safely used. • Do not operate when charging. • Dispose of the monitor when its service life is reached. Follow local regulations regarding the disposal of such product. • When the performance changes (such as: inaccurate measurement or abnormal display), please stop using it immediately and contact the after-sales service personnel in time.
• DO NOT use this monitor on infants, toddlers, children or persons who cannot express themselves. • DO NOT adjust medication based on readings from this blood pressure monitor. Take medication as prescribed by your physician. ONLY a physician is qualified to diagnose and treat high blood pressure. • DO NOT use this monitor on an injured arm or an arm under medical treatment. • DO NOT apply the arm cuff on your arm while on an intravenous drip or blood transfusion.
• To help avoid strangulation, keep the air tube and type C cable away from infants, toddlers and children. • Stop using this monitor and consult with your physician if you experience skin irritation or discomfort. • Consult with your physician before using this monitor on an arm where intravascular access or therapy, or an arterio-venous (A-V) shunt, is present because of temporary interference to blood flow which could result in injury.
• DO NOT use this monitor in a moving vehicle such as in a car. • DO NOT drop or subject this monitor to strong shocks or vibrations. • DO NOT use this monitor in places with high or low humidity or high or low temperatures. • Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
7. Classification of BP (Blood Pressure) ACC/AHA 2017 Hypertension guidelines define categories of BP in adults as below. Categories of BP in Adults* BP Category Systolic BP Normal < 120 mmHg Diastolic BP < 80 mmHg Elevated 120 - 129 mmHg < 80 mmHg 130-139mmHg or 80-89mmHg or Hypertension Stage 1 Stage 2 ≥ 140 mmHg ≥ 90 mmHg * Individuals with Systolic BP and Diastolic BP in 2 categories should be designated to the higher BP category.
(2) Display screen 9.Preparation Install the battery Open the battery cover according to the method shown in the figure. Place 4 AAA dry batteries in the battery compartment, and pay attention to the electrode indication of the batteries. Install the battery as indicated in the picture right under this sentence.
(2)Battery replacement If the product is not used for a long time (over 3 months), please take out the batteries. (3)Type C connection for power supply (The cable is optional) The product power can be supplied by plugging into DC 5V external power supply through a Type C interface. 10.Function Setting (1) User mode In standby mode, press the " " button to enter the user group selection interface. Then press the " to switch and select user groups.
(2) Year/month/date setting In standby mode, press " " for about 3 seconds to enter the date setting, and "year" will flash. Press " the desired year, and then press " " to adjust to " to confirm the selection. When the "year" is set, it will automatically enter the month setting. At this time, the "month" icon will flash. You can switch to the desired value by pressing the " " button. Follow the same step to set "date", "hour", and "minute".
the voice setting (the screen will display "SP"). Press “ " button to turn on or turn off the sound, "ON" means turn on the sound, "OFF" means turn off the sound, press " button to confirm the select; 2)Voice broadcast content: Attention, please! Please keep silent and relax. Keep the cuff at the heart level. ①If your blood pressure is in normal range: Thank you. Your blood pressure is: Systolic pressure xxx millimeter of mercury pillar. Diastolic pressure xx millimeter of mercury pillar.
Thank you. Wish you a good health. ②If your blood pressure is not in normal range: Measuring result is abnormal. Your blood pressure is high/low Could not measure your pulse at this time.
kPa mode mmHg mode 11.How to Take Proper Measurements (1) Preparation before measurement --Remove the clothing on the arm. --Always measure in the same arm (generally the left arm). --Remain still and keep quiet during measurement. --Relax as much as possible and do not talk during measurement. --Measure your blood pressure at about the same time every day. --Do not measure right after physical exercise or a bath. Rest for 20 to 30 minutes before taking the measurement.
(2) Applying the arm cuff 1) Connect the arm cuff to your monitor by inserting the air plug into the air jack securely. 2) Place your hand through the cuff loop. Pull the cuff until it reaches your upper left arm.
Note • The bottom edge of the arm cuff should be 0.79-1.18 inches (2 to 3 cm) above the inside elbow. The air tube is on the inside of your arm and aligned with your middle finger. 0.79-1.18 inches (2 to 3 cm) Bottom edge 3) Make sure that the air tube is positioned on the inside of your arm and wrap the cuff securely, so it can not move around your arm.
(3)Sitting correctly 15
Note: If you feel uncomfortable during the measurement, press the " " button immediately to stop measure. when the air pressure is filled to a certain value, the value on obtained. (5)Memory function 2)In standby mode, press the “ button once and the device will display the average value of the blood pressure Measured for the fist three times. Press the button again, the first memory will be displayed. Press the button again and the rest memories will be displayed one by one.
will appear on the screen. (7)Self check for cuff strap The " " icon is always displayed on the screen when the cuff is wore correctly. When the cuff is wore too loosely, the " " icon will always flash to remind you. If the" is flashing all the time, please press the " measurement. " icon " button to stop the (8)“Keep Still” indication The " " icon flashes when the body moves during the measurement, which may cause incorrect measurement results. Please re-measure it. 12.
Keep dry Low voltage prompt Keep out of the sun Vertical upward IP21 The device is protected against splashing water. Water splashed against the enclosure from any direction shall have no harmful effects. RoHS RoHS mark CE0123 CE mark Manufacturer Date of manufacture Serial number Lot number EU authorized representative 13.Common Q & A on Blood Pressure Q1.
(2.7 kPa - 4.0 kPa) lower than that measured in hospitals. It is because people are nervous when measured in hospitals, while they tend to be in a stable mood when measured at home. It is important to understand the normal blood pressure when you are at home. 2) If the cuff is placed in a position above the heart, the measured blood pressure is low, so please measure in the correct posture. Q2.
might be increased due to the abdominal pressure or due to the arm position lower than the heart. → Please make measurement in correct posture. Q3. When will the measurement be better? Please make measurement in the morning after you get up to urinate or when your body and mood are in stable state. It is better to make measurement at the same time every day. Q4. Why the blood pressure value measured each time is different? 1) When systole each time, the blood pressure will change to some extent.
compressed, resulting that the finger tip blood does not flow smoothly, If you continue the measurement in case of extravasated blood, you cannot obtain the correct measured value. Loosen the arm band, raise your hand over the head, and grasp and stretch your left and right palms for 15 times repeatedly. Then the extravasated blood can be dissolved, and you can continue the blood pressure measurement. 2) Cuff position and twining method. The measured value varies with the cuff size.
LCD display information Er U Remark The inflation can not reach 30 mmHg in 12 seconds. Er H The inflation reaches 295mmHg, it deflates automatically after 20ms. Er 1 The pulse rate is not detected correctly. Er 2 Too much disturbance(Move, talk, or magnetic disturbance during a measurement.) Er 3 The test result is abnormal.
No Whether the air pressurizi tube is broken or ng leaked? Whether the arm is Purchase a new cuff Keep your arm and Unable to moved when measure pressurization due to Whether you talk Keep quiet while display during measuring the blood error measurement pressure body still static Whether the cuff is twined too loose Please tighten the cuff Air leakage Whether the air of cuff bag of cuff is Replace with new cuff ruptured If the blood pressure still cannot be measured normally by
Do not use any corrosive cleaning agent. When cleaning, be careful not to immerse any part of the monitor to avoid liquid flow into the instrument. It is suggested to clean once every week. Complete the cleaning in 3min each time. The number of repeated cleaning each time shall not exceed 3 times. 15.
each time. Each time of disinfection shall be completed within 1min. The number of repeated disinfection each time shall not exceed 2 times. Cleaning and disinfection shall be carried out in the following environment: temperature: +5℃~+40℃ (50℉104℉)+ relative humidity: 15%~80%RH, non-condensing, atmospheric pressure: 70kPa~106 kPa. 15.3 Disposal Dispose of your monitor, other components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
- Always keep the surface of monitor clean and tidy, helpful to prolong the service life of Blood Pressure Monitor. - If the host is dirty, please wipe with a dry soft cloth. If the dirt cannot be eliminated easily, wipe with a soft cloth stained with water or neutral detergent, and then dry with a dry cloth. -No maintenance or maintenance required when using the device. Do not allow water or other liquids to flow into the host. 17.
Pressure value Accuracy SYS: 57-255 mmHg; DIA: 25-195 mmHg; Measuring range Pulse rate 40-199 bpm Pressure value ±3 mmHg Pulse rate ±5% bpm Low battery 4.2V±0.1V: low battery; <4.0V±0.
Temperature 5℃-40℃ condition Operating Humidity Environment condition If stored or used beyond 15%-90%RH the designated temperature Atmospheric 70kPa-106kPa and humidity range, it will not condition be used properly Transportation and Avoid strong impact, direct impact, exposure or Storage rain during transportation.
RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC610003-2 Voltage fluctuations/ flicker emissions IEC610003-3 Group 1 The Arm Blood Pressure Monitor uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
Electrostatic discharge (ESD) IEC 61000-4-2 ±8kV contact ±2 kV,±4kV,±8 kV, ±15kV air ±8 kV contact ±2 kV,±4 kV, ±8 kV,±15 kV air Electrostatic discharge (ESD) IEC 61000-4-2 ±8 kV contact ±2 kV,±4 kV, ±8 kV,±15 kV air ±8 kV contact ±2 kV,±4 kV,±8 kV, ±15 kV air Electrical fast transient/burst IEC 61000-4-4 Not applicable Not applicable Surge IEC 61000-4-5 Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 Power frequency Magnetic field IEC 61000-4-8
Radiate d RF IEC6100 0-4-3 (Test specifica tions for ENCLO SURE PORT IMMUNI TY to RF wireless commun ications equipme nt) Test Frequ ency( MHz) Band (MHz) Servi ce Modul ation 385 380390 TETR A 400 Pulse modul ation 18 Hz 450 430470 GMR S 460, FRS 460 710 70 4-7 87 LTE Band 13, 17 80 0-9 60 GSM 800/90 0, TETRA 800, iDEN 820, CDMA 850, LTE Band 5 GSM 1800; CDMA 1900; GSM 1900; DECT; LTE Band 1, 3, 4, 25; UMTS Blueto oth, WLAN, 745 780 810 870 930 1720 1845 1 70 0– 1 99 0 1970 2450 2 40
5240 5500 5785 2 57 0 802.11 b/g/n, RFID 2450, LTE Band 7 217 Hz 5 10 05 80 0 WLAN 802.11 a/n Pulse modula tion 217 Hz 0,2 0.3 9 9 FCC Caution: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules.
Shenzhen AOJ Medical Technology Co., Ltd. Room 301&4F, Block A, Building A, Jingfa Intelligent Manufacturing Park, Xiaweiyuan, Gushu Community, Xixiang Street, Bao'an District, 518126 Shenzhen, CHINA Email : info@aojmedical.
Website : https://www.aojmedical.com Tel : 86-755-2778 6026 Share Info Consultant Service LLC Repräsentanzbüro Address: Heerdter Lohweg 83, 40549 Düsseldorf Tel:0049 179 5666 508 E-mail: EU-Rep@share-info.
Manual version: A0 Software version: V1.