User's Manual
19" LCD MONITOR
REV A
21
Status Current display settings can be called here
in the respective picture mode: Operate
hours of display, firmware version, OSD
version, configuration version, current
source, current temperature, current timing
of input signal, current LUT inside the
monitor.
Service level 2 Settings in this menu must only be carried out by service person*
Quit OSD menu
Accept changes
Reject changes
Quick OSD menu and either save or reject
the changes.
If you have reached this menu
unintentionally, you can return to the main
menu using the EXIT key.
OSD is locked
If this message is displayed, you do not
have the authority to carry out the changes
in the OSD menu.
Please contact your servicing partner in this
case.
* Service level 2 enter: while the highlight line is on the service level 2 position, press 1 x Up, and 2 x Down keys, it will
enter the following submenu.
Service
level2
LUT select and factory settings recall: Contrast; Brightness; Backlight; Setting1;
OSD position; corresponding LUT factory recall. (The default state is
Gamma2.2LUT)
CIE Select CIE LUT
DICOM Select DICOM LUT
Gamma 1.8 Select Gamma 1.8 LUT
Gamma 2.0 Select Gamma 2.0LUT
Gamma 2.2 Select Gamma 2.2 LUT(default)
Native Select panel native characteristics
FACTORY RESET Load the factory setting