User's Manual

Last change:
Dec 23, 2016
Torch Bigtide Digital Technology Co., Ltd.
Page 29 of 32
0.04<W0.08
10
10
interval
=20mm
10<L25
2
>25
0
0.08<W0.1
3
1
>0.1
0
c. Stain
The heavy or distinct stains visible under transmission inspection are not allowed. Light strains visible
only under reflection inspection conditions are acceptable. Stains that do not exceed the circular or
linear defect criteria are allowed.
d. Fractures
None allowed.
8. NOTICE FOR HANDING
(1) When the module is assembled, it should be attached to the system firmly using all
mounting holes. Be careful not to twist or bend the modules.
(2) Because the inverters use high voltage, power should be disconnected before it is
assembled or disassembled.
(3) Refrain from string mechanical shock and /or any force to the module. In addition to
damage, this may cause improper operation or the module and backlight.
(4) Note that polarizers are very fragile and could be easily damaged. Do not press or
scratch the surface using the harder than a HB pencil lead.
(5) Wipe off water droplets or oil immediately. If you leave the droplets for a long time,
staining and discoloration may occur.
(6) If the surface of the polarizer is dirty, clean it using some absorbent cotton or soft
cloth.
(7) The desirable cleaners are water, IPA (Isopropyl Alcohol) or Hexane. Do not use
Ketone type materials (ex. Acetone), Ethyl alcohol, Toluene, Ethyl acid or Methyl
chloride. It might damage to the polarizer due to chemical reaction.
(8) If the liquid crystal material leaks from the panel, it should be kept away from the
eyes or mouth. In case of contact with hands, legs or cloths, it must be washed away
thoroughly with soap.
(9) Protect the module from static which may cause damage to the CMOS Gate Array IC.
(10) Use fingerstalls with soft gloves in order to keep display clean during the
incoming inspection and assembly process.
(11) Do not disassemble the module.
(12) Do not pull or fold the lamp wire.
(13) Do not adjust the variable resistor located on the module.
(14) Protection film for polarizer on the module should be slowly peeled off just before
use so that the electrostatic charge can be minimized.