5.3 Mechanical requirements
Operation
Vibration
Random vibration, 1 G rms 5-200Hz for 2
hours duration, in the vertical direction.
Random vibration, 0.5 G rms 5-200Hz for
1hour duration, in the horizontal plane, in a
direction perpendicular to the front face of
monitor. Random vibration 0.5 G rms 5-200Hz
for 1 hour duration, in a horizontal plane, in a
direction parallel to the front face of the
monitor.
Packed unit
Vibration
Vibration : Random vibration, 1 G rms
5-200Hz for 2 hours duration, in the vertical
direction. Random vibration, 0.5 G rms
5-200Hz for 1hour duration, in the horizontal
plane, in a direction perpendicular to the front
face of monitor. Random vibration 0.5 G rms
5-200Hz for 1 hour duration, in a horizontal
plane, in a direction parallel to the front face
of the monitor.
5.4 Drop Test (packed)
Position
Height
Corner
1
50.0cm
Edge
3,2,4
50.0cm
Surfaces
A,B,C,D
50.0cm
E
50.0cm
F
50.0cm
(Cushion should be changed to new one.)
Corner
5
50.0cm
Edge
6,7
50.0cm