User's Manual
Last change:
2015-1-23
Copyright @Bigtide
All rights reserved
HL1936(HL1936SMT-L
/R internal) For GE
Page 18 of 37
of the monitor.
Color
Setting1
Setting 2
Setting 3
User
Set desired Brightness level:
Three fixed Brightness level are
available
The default value is:
Setting1: 500cd/m2; Setting2:
600cd/m2; Setting3: 700 cd/m2
While choose setting 1,2,3 state it
will recall factory default Black
level, Contrast, Backlight
H Position
(Analog only)
0…255 Shift picture in horizontal
direction
V Position
(Analog only)
0…255 Shift picture in vertical direction
Frequency
(Analog only)
0…100 Adjust the frequency and phase of
the input signal.
Hsync Phase
(Analog only)
0…63 Source clock phase
Display
Settings
Sharpness Interpolation filter -5
to 5
One of the 11 filters can be
selected for the sharpness setting
to reduce scaling artifacts.
Interpolation filters depend on
the input resolution. Digital
signals which is used with
1280X1024 resolution can not be
adjusted since each pixel is
controlled by its own pulse.
Other digital signals which is
lower than 1280 x 1024 can be
adjusted. Analog signals can be
adjusted in all supported
resolution.
Negative figure is adjusted to get
softer image and positive figure is
adjusted to get sharper image.
The user should individually
adjust the filter depending on
the application.
Input
Source
DVI-D
VGA
Select the active input source
priority.
If you call this OSD menu, the
current source is displayed. If
current source is inactive (NO
sync) and, it will auto search
other port.