User's Manual
Last change:
2015-1-23
Copyright @Bigtide
All rights reserved
HL1936(HL1936SMT-L
/R internal) For GE
Page 13 of 37
2.5.3 View angle
Left/Right and Up/Down typical 170 degree (CR≥10) (Note 2)
2.5.4 Brightness Uniformity
Deviation less than 30% (Note 5)
2.5.5 Contrast ratio
The panel’s native contrast ratio should be at least 800:1. (Note 3)
2.5.6 Response Time
Typical (Ton +Toff ): 30ms (Note 6)
2.5.7 Gamma Curve
Within ± 10% tolerance of calculated value
Factory Preset gamma value: CIE;DICOM; Gamma1.8, Gamma2.0, Gamma2.2
(Gamma2.2 is default setting)
Note1: Test Equipment Setups
The measurement should be executed in a stable, windless and dark room between 20
minutes after the backlight at the given temperature for stabilization of the backlight.
This should be measured in the center of screen. Test equipment should be equivalent
with the following equipment.
Environment condition: Ta=252C