User Manual

Last change:
2013-3-20
Copyright @ Shenyang
Torch-Bigtide Digital Tech.,Co.,Ltd
HL1530
Page 17 of 23
Ambient humidity 20%-80%
Temperature gradient
< 0.5°C/min
Atmospheric pressure range 70 – 110 kPa
4.2 Transport and Storage (Packed)
Tab. 4.2
Ambient temperature range -10 -- +40
Ambient humidity 10%-90%
Temperature gradient Max. 10/h, no condensation
Atmospheric pressure range 70 – 106 kPa
4.3 Mechanical Load
Operation UXN-13600 Class M2
Tab. 4.3 Vibration
Test direction X-direction
(user position)
Y-direction Z-direction
frequency range
cross-over frequency
10Hz - 150Hz
59.5Hz
10Hz - 150Hz
57.5Hz
10Hz - 150Hz
57.5Hz
acceleration 5g above the cross-over
frequency
2g above the cross-over
frequency
2g above the cross-over
frequency
displacement 0.7mm
peak-peak
up to the
cross-over frequency
0.3mm
peak-peak
up to the
cross-over frequency
0.3mm
peak-peak
up to the
cross-over frequency
sweep rate 1 octave/minute 1 octave/minute 1 octave/minute
initial sweep direction up up up
number of sweeps 10 10 10
Tab. 4.4 Bump
Test direction X-direction
(user position)
Y-direction Z-direction
Acceleration 25g 10g 10g
Pulse width 6 - 10 msec. 6 - 10 msec. 6 - 10 msec.
Number of bumps 4000 1000 1000
Packed unit:
According to 2M2 EN60721-3-2
5. REGULATION
5.1 Safety Specifications
Tab. 5.1
Safety standards
IEC60950-1FCC Part 15 Class B
CISPR 11 Group 1 Class B
Approvals
FCCCB (NCB Lab.)
Protection class class III