Installation Guide
9. Do not use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication
of damage.
10. Use 105°C wire copper conductors only.
11. Do not operate EV700 in temperatures outside its operating range.
For charging stations set to 16-48 A, the range is -22˚F to 122˚F (-30˚C to 50˚C). For charging stations set to 50 A, the range is
-40˚ to 113˚F (-40 to 45˚C).
12. When using the EV Charger in an inside location such as a garage, position the EV Charger’s main controller at
least 18 inches (46 cm) above the floor.
13. Disconnect from all power sources before servicing unit.
14. For outdoor use, the pedestal shall be located at a height between 600 mm (24 inches) and 1.2 m (4 feet) above
grade;
For indoor use, the pedestal shall be located at a height between 450 mm (18 inches) and 1.2 m (4 feet) above grade;
15.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
FCC Caution:
Changes or modifications not expressly approved by the part responsible for compliance could void the user's authority to
operate the equipment.
FCC RF Radiation Exposure Statement Caution: This Transmitter must be installed to provide a separation distance of at least
20 cm from all persons.
FCC Statement:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required
to correct the interference at his own expense.
IC statement:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur
de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.