Collector 1 st. tank
Collector 1 st. tank
70|
Steca Elektronik GmbH | 87700 Memmingen | Germany | Fon +49 (0) 8331 8558-0 | Fax +49 (0) 8331 8558-132 | www.stecasolar.com
|71
Steca Elektronik GmbH | 87700 Memmingen | Germany | Fon +49 (0) 8331 8558-0 | Fax +49 (0) 8331 8558-132 | www.stecasolar.com
Steca TR 0301 U
The TR 0301 U controller was specially developed for the
North American market based on the TR 0301 basic con-
troller. With its highly fireproof case and special certifica-
tion (ETL label) from a Nationally Recognized Testing La-
boratory (NRTL) in the US, the controller meets the safety
standards and minimum requirements needed in order to
be sold and distributed in North America.
A feature of the TR 0301 series of controllers is the anima-
ted graphic display, which offers a complete visualisation
of the solar system’s operating mode and solar circuit.
The clearly arranged display ensures easy operation using
pictograms. The controller was jointly designed with an
internationally renowned design centre. The controller
is used for monitoring and controlling solar thermal sys-
tems which have a collector array and a storage tank. In
addition, the controller also has important system moni-
toring and safety functions to ensure safe and durable
operation of the entire system. The numerous additional
functions of the TR 0301 also include the option of limi-
ting the storage tank temperature, a tube collector func-
tion, an antifreeze function, a holiday and storage re-cool
function as well as a choice of temperature indications in
either degrees Celsius (°C) or Fahrenheit (F°). The operati-
onal safety of the system is supported by a sophisticated
fault diagnosis. The multi-coloured LCD backlight ensures
quick and safe location of occurring errors and facilitates
quick troubleshooting.
The TR 0301 U controller is supplied with a pre-fitted US
mains connection cable and a preinstalled, pluggable
pump output.
Steca TR 0301sc
The controller TR 0301sc is the RPM-controllable version
of the basic controller TR 0301. In addition to the speed
control of the solar circuit pump, the TR 0301sc also al-
lows logging of the solar circuit pump‘s hours of opera-
tion, as well as recording the minimum and maximum
temperature values from the collector and the storage
tank. The controller is used for monitoring and control-
ling solar thermal systems which have a collector array
and a storage tank. With its animated graphic display,
which is clearly arranged, the TR 0301sc visualizes the
operational status as well as the complete solar circuit of
the solar energy system. The consistent use of pictograms
helps make the controller easy to operate. The control-
ler also performs important system monitoring and sa-
fety functions to ensure safe and long-lasting operation
of the entire system. The numerous additional functions
of the TR 0301sc include the option of limiting the sto-
rage tank temperature, a tube collector function, an anti-
freeze function, a holiday and storage re-cool function,
as well as a choice of temperature indications in either
degrees Celsius (°C) or Fahrenheit (°F). The operational sa-
fety of the system is supported by a sophisticated fault
diagnosis. The multi-colored LCD backlight ensures quick
and safe location of occurring errors and facilitates quick
troubleshooting.
Features
Backlight LCD-Display
Functioning of solar energy system shown
in animated display
Compact, 3 piece designer case
Speed control of solar circuit pump
Tube collector function
Holiday (storage recool) function
Limitation of storage tank temperature
Temperature display °C / °F
Logging of solar circuit pump operating hours
Minimum and maximum displays of the storage tank
and collector temperatures
134
137
38
Temperature Differential Controller TR 0301sc
System voltage 230 V (± 15 %), 50 Hz
[optional 115 V (± 15 %), 60 Hz]
Max. own consumption ≤ 1 W
Inputs 3
3 x temperature determination (Pt1000)
Output 1
1 x R1 triac for speed control,
max. 200 W [230 V]
Turn-on temperature difference 8 K
Turn-off temperature difference 4 K
Operation temperature range 0 °C...+45 °C
Animated LCD-Display 2 colour backlight
Protection class IP 20 / DIN 40050
Weight 250 g
Dimensions l x w x h 137 x 134 x 38 mm
INPUTS
3
OUTPUT
1
INPUTS
3
OUTPUT
1
Features
Backlight LCD-Display
Animated representation of solar system functions
Compact, 3-piece designer case
Anti-freeze function
Tube collector function
Holiday (storage re-cool) function
Limitation of storage tank temperature
Temperature display for storage tank and collector
Pump operating status display
Temperature sensor monitoring and system
monitoring
Temperature display °C / °F
LQFK
PP
LQFK
PP
LQFK
PP
Temperature Differential Controller TR 0301 U
System voltage 120 VAC, 60 Hz
[optional 240 VAC, 60 Hz]
Max. own consumption ≤ 1 W (≤ 0.001 HP)
Inputs 3
3 x temperature recording (Pt1000)
Output 1
Switch relay; switching performance
max. 400 W (0.5 HP [120 V~]) or 800
W (1 HP [240 V~])
Turn-on temperature difference 8 K (46.4 °F)
Turn-off temperature difference 4 K (39,2 °F)
Operation temperature range 0 °C ... +45 °C (32 ... +113 °F)
Animated LCD-Display 2 colour backlight
Protection class IP 20/DIN 40050
Weight 0.55 kg (19.54 oz) including cable
Dimensions l x w x h 160 x 157 x 47 mm
6.3“ x 6.18“ x 1.85“
Temperature sensors
2 x Pt1000
Collector sensor: 59 inch (1.5 m)
silicone cable with bushing
(Measuring range up to +356 °F
(+ 180 °C))
Storage tank sensor: 11.8 inch (0.3 m)
twisted single conductor flat surface
sensors with compression cable lug
(Measuring range up to 222 °F
(+105 °C))
System with 1 storage tank
*optional
*
System examples
Technical data
System examples
System with 1 storage tank
System with 1 storage tank and
3 temperature sensors
Technical data
Temperature
Differential
Controller
Seiten müssen noch
getauscht werden
Temperature
Differential
Controller