Crash-Rated Fortified Barrier Arms
StrongArm M50
™
K12 Crash Barrier
Crash certified to ASTM F2656-07 P2 standard, stopping a
15,000 lb. (6.8 metric tons) truck traveling 50 mph (80 km/h).
Penetrated less than 1.3 meters.
The StrongArm M50
™
is a high cycle, M50-P2 crash tested, fortified
barrier arm. This operator runs with the ultra-reliability of HySecurity's
30 year proven hydraulics, the flexibility, power, and reliability of
HySecurity's programmable Smart Touch
®
Controller, and unique
functional and safety benefits. Installation is easy and inexpensive with
integrated hydraulics and controls. StrongArm M50
™
is available to fit 12
to 24 foot clear openings, is rated to cycle up to 100 times per hour for
one vehicle, and runs at 7 to 10 seconds open/close depending on arm
length. EFO is 6 to 8 seconds.
Strong Arm M50
™
, 12' long arm length
113482
$33,646
Strong Arm M50
™
UPS, 12' long arm length, UPS backup*
113483
$38,646
Strong Arm M50
™
, 16' long arm length
113484
$34,595
Strong Arm M50
™
UPS, 16' long arm length, UPS backup*
113485
$39,960
Strong Arm M50
™
, 20' long arm length
113486
$36,195
Strong Arm M50
™
UPS, 20' long arm length, UPS backup*
113487
$41,195
Strong Arm M50
™
, 24' long arm length
113488
$37,600
Strong Arm M50
™
UPS, 24' long arm length, UPS backup*
113489
$42,600
*(DC battery backup for full functionality during power loss)
StrongArm M30
™
K4 Crash Barrier StrongArm M50
™
K12 Crash Barrier
Crash Certified M30, P1-ASTM F2656-07 M50, P2-ASTM F2656-07
Shallow Mount 6' x 6' x 2' (1.83 m x 1.83 m x .6 m) n/a
Deep Mount 4' x 4' x 4' (1.22 m x 1.22 m x 1.22 m) 6' x 6' x 4' (183 x 183 x 122 cm)
Duty Cycle Continuous Duty* Continuous Duty*
Horsepower 2 hp 2 hp
Open/Close Time
6 seconds to 8 seconds
depending on arm length
7 seconds to 12 seconds
depending on arm length
Emergency Fast
Close Time (EFO)
5 seconds to 7 seconds
depending on arm length
6 seconds to 8 seconds
depending on arm length
Clear Opening
12 ft. to 24 ft. in 2 ft. increments
(366 cm to 732 cm in 61 cm increments)
12 ft. to 24 ft. in 2 ft. increments
(366 cm to 732 cm in 61 cm increments)
Ingress
Protection
IP56 IP56
Temperature
Rating
-40˚ F to +158˚ F (-40˚ C to +70˚ C)
using Uniflow fluid
-20˚ F to 158˚ F (-4˚ C to 70˚ C)
using biodegradeable fluid
-40˚ F to +158˚ F (-40˚ C to +70˚ C)
using Uniflow fluid
-20˚ F to 158˚ F (-4˚ C to 70˚ C)
using biodegradeable fluid
1 Phase Power 208V - 230V, 50/60 Hz 20A 208V - 230V, 50/60 Hz 20A
3 Phase Power
208V - 230V, 50/60 Hz 20A
380V - 480V, 50/60Hz 15A
208V - 230V, 50/60 Hz 20A
380V - 480V, 50/60Hz 15A
Warranty 5 year 5 year
UPS backup
Model
StrongArm M30 UPS StrongArm M50 UPS
*100 cycles per hour *100 cycles per hour
4,000 PSI concrete (minimum) 48 in. (122 cm)
53¼ in.
(135 cm)
73 in.
(1.8 m)
86½ in.
(220 cm)
C
/
L
18 in.
(46 cm)
C
/
L
34 in. (86 cm)
Clear Opening
Drawing Not to Scale
53¼ in.
(135 cm)
73 in.
(1.8 m)
86½ in.
(220 cm)
C
/
L
18 in.
(46 cm)
C
/
L
34 in. (86 cm)
Clear Opening
24 in. (61 cm)
Drawing Not to Scale
Dim shown to bottom of plate
3,000 PSI concrete (minimum)
6 ft. (183 cm)