For Your Safety Thank you for choosing this Shell product. Please read the following instructions and keep them for future reference. This instruction manual contains important information on safe operation and use. To ensure long life and performance reliability, please operate and maintain as per the instructions on this sheet.
Package Includes • 1 x Eyelet Terminal Connectors • 1 x Battery Charger • 1 x User Guide • 1 x Fused Battery Clamps • 1 x Product Warranty Registration Product Features • Designed for charging 12V Li-ion batteries and 6V and 12V lead acid batteries including Wet, Gel, MF, VRLA and AGM batteries • 7-step charging cycle optimizes charging efficiency and battery life • Maintenance mode ensures batteries of any capacity are always ready to use • 7 levels of safety protection Operating Instructions Charging
Before connecting to the battery 1. Check the battery chemistry and voltage before charging it with our product. The battery information can be found in the vehicle's owner's manual. 2. Turn off the power loads such as headlamps, air-conditioning and radio before charging the battery. Charging setup 1. Connect the battery clamps or eyelet terminal connectors to the DC connector of the battery charger. 2. Plug the charger into an outlet. The red power Indicator will turn on.
LED Indicator Light Table LED Indicator Indicator Light ERR Red light on Power indicator.
Pulse The battery undergoes the desulfation process to break down the sulfate and to restore the battery capacity. Recondition This stage reactivates the battery for bulk charging after desulfation. Bulk Charging The battery is charged at a constant current of 1A. This stage will charge the battery to approximately 85% of full charge. Absorption The charger switches to constant voltage charging.
Troubleshooting Table Problem Power indicator light does not turn on Possible Cause Solution Charger is not plugged into the outlet properly Make sure the charger is plugged into the outlet securely. AC outlet is not supplying power Turn the switch on if the outlet is connected to a switch. Check for open fuse or circuit breaker.
Specifications Input: 100 - 120V ~ 60Hz 20W Output: 12V 1A 6V 1A Battery Type: Lead-acid including Wet, GEL, AGM, VRLA and MF, and Li-ion (LiFePO4) Battery Capacity: 2-20 Ah; maintain all sizes Battery Voltage: 6V & 12V DC Cable: 78 inches/198.1 cm Operating Temperature: -10°C to 45°C Storage Temperature: -20°C to 55°C Product Dimensions: 3.56 x 2.47 x 1.98 inches/90.42 x 62.0 x 50.29 mm Product Weight: 0.38±0.02 lb/175±10 g Accessories: Battery Clamps: 27 inches/68.
Safety Instructions Failure to follow the instructions may cause serious injury, death or property damage WARNING: Risk of electric shock, explosion and fire WARNING: Risk of explosive gases Working in the vicinity of a Lead-acid battery is dangerous. Battery generates explosive gases during normal operation.
• Do not put cables on or near moving parts such as hoods, doors, fans and belts. • Do not allow the clamps to touch each other. • Keep out of reach of children. Personal Precautions • Wear adequate eye protection and protective clothing when working near a car battery. • Do not smoke or allow a spark or flame near the battery or engine. • Remove all metal objects such as rings, bracelets, and watches. • Have plenty of fresh water and soap nearby in case of battery acid contact with eyes, skin or clothing.
radio communications. However, there is no guarantee that interference will not occur in a particular installation.
Shell Five (5) Years Limited Warranty Shell warrants that this product (the "Product") will be free from defects in material and workmanship for a period of five (5) years from the date of purchase (the "Warranty Period"). For defects reported during the Warranty Period, Shell will, at its discretion, and subject to Shell’s product support analysis, either repair or replace defective Product.
FOR WARRANTY SERVICE.
Battery Charger & Maintainer SBC100 SH SBC100 IM ENG D10057R2 Printed in China