Unit installation

HP800A-1E
40º-105º
BTUH/COP
82,000/3.5
127,000/4.7
Auto/Internal
Ext. Field Install
15-90
2.2@30GPM
60º-105ºF
2"PVC
208 or 230
1 Phase
#6
60
1/3
1.9
4,250
1,075
22"
Vertical
33.7
141
410A
3 Lbs. 8 Oz.
Composite
Yes
298
35.5"H
31.5"W
36.75"L
Factory Specifications
MiniMax® Plus HP
Pool/Spa Heat Pumps
HP400A-1D
40º-105º
BTUH/COP
62,000/3.2
99,000/4.6
Auto/Internal
Ext. Field Install
15-90
2.2@30GPM
60º-105ºF
2"PVC
208 or 230
1 Phase
#8
50
1/3
1.9
4,250
1,075
22"
Vertical
27.5
119
410A
3 Lbs. 2. Oz.
Composite
Yes
270
27.25"H
31.5"W
36.75"L
HP1000A-1E
40º-105º
BTUH/COP
95,000/3.4
145,000/4.5
Auto/Internal
Ext. Field Install
15-90
3.1@50GPM
60º-105ºF
2"PVC
208 or 230
1 Phase
#6
60
1/3
1.9
4,250
1,075
22"
Vertical
34.5
142
410A
3 Lbs. 8 Oz.
Composite
Yes
298
35.5"H
31.5"W
36.75"L
HP600A-1D
40º-105º
BTUH/COP
68,000/3.0
115,000/4.5
Auto/Internal
Ext. Field Install
15-90
2.2@30GPM
60º-105ºF
2"PVC
208 or 230
1 Phase
#8
50
1/3
1.9
4,250
1,075
22"
Vertical
29.2
145
410A
3 Lbs. 2. Oz.
Composite
Yes
270
27.25"H
31.5"W
36.75"L
* Standard for Heating and Cooling Equipment (UL 1995, 2
nd
Edition and CAN/CSA C22.2 No. 236, 2
nd
Ed.) 3 phase units performance not within scope of ETL testing procedure. Specifications may change without notice. The actual wire
or breaker required may be larger and must be determined by local licenced electrician to meet United States local building safety codes. Minimum suggestion
only
. Products covered by Patent No.: US 6,227,003 B1, other patents pending.
HP1000A-3E
40º-105º
BTUH/COP
95,000/3.4
145,000/4.5
Auto/Internal
Ext. Field Install
15-90
3.1@50GPM
60º-105ºF
2"PVC
208 or 230
3 Phase
#10
40
1/3
1.9
4,250
1,075
22"
Vertical
27.9
129
410A
3 Lbs. 8 Oz.
Composite
Yes
298
35.5"H
31.5"W
36.75"L
CP12A-3B
40º / 105º
BTUH/COP
160,300/4.7
230,500/6.5
Auto/Internal
Ext.Field Install
30-100
2.5 @ 60 GPM
60º-105ºF
2"PVC
208 or 230
3 Phase
#6
60-90
3/4
6.2
6,300
1,075
22"
Vertical
39.7
254
R-22
10
Composite
Yes
475
35.5"H
31.5"W
36.75"L
460512 460513 460514 460515 460521 460526
Pentair Model Order Number
Model Number
Min./Max. Air Inlet Temperature (ºF)
Air Temperature Relative humidity
50.0˚F 63%
80.6ºF˚ 63%
Water Flow & Plumbing Characteristics
Water Bypass Type (up to 1.5 HP pump)
Water Bypass Type (2 HP pump or above)
Min./Max. Water Flow Rate ( GPM )
Condenser Pressure Drop ( PSI )
Min./Max. Water Inlet Temperature ( ˚F )
Plumbing Connection Size ( In. Slip )
Electrical Characteristics
60 Htz Dual Rated Supply Voltage( VAC )
Supply Voltage Phase
Min Sup.Wire Size Copper Strand(AWG)
Min. HACR Breaker or Fuse(AMP)
Evaporator Fan Motor ( HP )
Fan Full Load Amp (FLA )
Air Flow (CFM)
Fan Speed (RPM)
Fan Diameter (Inches)
Fan Discharge
Compressor Rated Load Amps (RLA)
Compressor Locked Rotor Amps (LRA)
Refrigerant Characteristics
Refrigerant Type
Initial Factory Refrigerant Charge (Lbs.)
Physical Characteristics
Cabinet Construction
Separate Electric Compartment
Weight (Lbs.)
Dimensions (inches)
See installation manual for
other important details!