PRE-START UP PROCEDURES
20
CHECK FLOW AT AUTO BYPASS
Make sure the pump is running with a full prime. Elimi-
nate any suction leaks that allow air into the system.
Confirm that the internal automatic bypass valve is work-
ing properly. Turn the power to the heater "OFF"
Confirm there are no air leaks at the pump skimmer
basket.
The auto valve should have no air passing through it.
Air pumped through the heater due to a suction leak on
the existing pool filtering system will cause turbulence
and physical erosion to the heat exchanger.
NOTE: COMPRESSOR TIME DELAY
BE AWARE THERE IS A 5 TO 7 MINUTE TIME DE-
LAY BEFORE THE COMPRESSOR WILL START
ONCE THE UNIT IS TURNED ON OR WHENEVER
IT RESTARTS.
SET THE WATER PUMP TIMER
Set the circulation pump timer for 24 hours until the
pool reaches temperature. Then it can be reset for 8 to
18 hours per day, depending on pool size and weather
conditions, time of the year, some fall/winter condi-
tions may require a 24 hour run time.
Auto
Bypass
Valve
IN
OUT
PVC TO COPPER COMPRESSION
FITTING
Once the water is flowing, examine the water tubing at
the two p.v.c. to copper compression fittings. If you see
a leak here call the factory warranty service department.
Plumbing
Manifold
Heat
Exchanger
ON
Tripper
Peg
COMMON 24Hr. MECHANICAL TIMER
OFF
Tripper
Peg
PVC Flex Pipe
1" M.A.
Compression
Assembly
Tubing to Heat
Exchanger