Service manual

X&XV1
E/A
No.
Adjusting point
Adjusting conditions
Adjusting proceduri
14 Video picture
1.
Make the following choice:
l
Using the membrane switch or the remote control
adjustment
Group
:
VIDEO 1
button, adjust the black-to-white (100%) level
differ-
Subject
:
PICTURE
ence
to 1
.l
+0.02
Vp-p.
2. Connect the oscilloscope
between pin (2) of
P801
and GND.
u
/
~~
-.,:~~vp-p
15 Video AGC
1.
Feed the NTSC split colour
l
Using the membrane switch or the remote control
bar signal.
button, adjust the black-to-white (100%) level
differ-
Group
:
VIDEO 1
ence
to 0.9
+0.02
Vpp.
Subject
:
AGC
2. Connect the oscilloscope
between pin (2) of
P801
and GND.
16 Video
brightness
adjustment
1. Feed the NTSC black
sig-
l
Using the membrane switch or the remote control
nal.
button, decrease 2 points from the level where the
Group
:
VIDEO 1
black signal becomes bit-less (dotted).
Subject
:
BRIGHT
2. Press the membrane switch
or the remote controls mute
button (to set the gamma
correction to the process
setting).
17 Tint
1.
Feed the NTSC colour bar
l
Using the membrane switch or the remote control
signal.
button, adjust the data to have the -(B-Y) waveform
Group
:
VIDEO 1
downhill straight.
Subject
:
TINT
2. Connect the oscilloscope to
pin (5) of
P801.
18 NTSC colour
1. Feed the NTSC colour bar
l
Using the membrane switch or the remote control
saturation level
signal.
button, adjust the difference between the 100% white
Group
:
VIDEO 1
portion and the red portion to 0.1
3~0.02
Vp-p.
Subject
:
N-COLOR
2. Connect the oscilloscope to
100% White Red
pin (1) of
P801.
24