Service manual

XG-XV1
E/A
No.
Adjusting point
Adjusting conditions
Adjusting procedure
8
RGB
counter-
1. Feed the black-and-red
0’
Using the membrane switch or the remote control
voltage
(25%) stripe signal (XGA).
button, adjust the
data
in order to minimize the flicker.
adjustment
If such a pattern signal is
0’
Make the same adjustment for BC (B) and GC (G).
not available, select the
:
horizontal stripe signal from
the desktop pattern menu.
2. Make the following choice:
Group
:
OUTPUT 3
Subject
:
RC
(R)
9 RGB gradation
1.
Feed the XGA green-only
l
Adjust the Gl-GAIN data until the first and second
regeneration
gradation pattern (more
gradations can be slightly recognized. (First
gradu-
adjustment
than 16 steps) signal.
ally raise the Gl-GAIN level until the gradation gets
Group
:
OUTPUT 1
recognized, and then adjust the level by lowering it
Subject
:
Gl-GAIN
again.)
10 RGB white
balance
1.
Feed the XGA gray scale
l
Choose the subjects Rl -BLK and Bl -BLK and adjust
signal.
the black balance of the gradation. Choose the sub-
Group
:
OUTPUT 1
.jects Rl-GAIN and Bl-GAIN and adjust the gray-to-
Subject
:
Rl-BLK
while balance (so that the entire screen looks
colour-
Rl -GAIN (R)
i
less).
Bl
-BLK
Bl-GAIN
(B)
’
11 NTSC 4fsc
1.
Choose the group VIDEO 1
l
Turn C450 to have the frequency counter read
to keep the unit without
sig-
14.31818 MHz
_t50
Hz.
nal.
2. Select the colour system
into
N358.
3. Connect the frequency
counter between
TP401
and GND.
12 PAL 4fsc
1. Choose the group VIDEO 1
l
Turn C446 to have the frequency counter read
to keep the unit without
sig-
17.734475 MHz
*50
Hz.
nal.
2. Select the colour system
into PAL.
3. Connect the frequency
counter between
TP401
and GND.
13 Horizontal
center
1. Feed the NTSC mono-
* Using the membrane switch or the remote control
scope pattern signal.
button, adjust the data to have the same overscan.
Group
:
VIDEO
1
Subject
:
NTSC-H
23