Service manual

19
XG-P20XU
XG-P20XE
XG-P20XD
Condition
The internal
temperature is
abnormally high.
The lamp does
not light up.
The POWER
indicator flashes
in red when the
projector is on.
Problem
· Blocked air intake.
· Clogged air filter.
· Cooling fan breakdown.
· Internal circuit failure.
· Burnt-out lamp.
· Lamp circuit failure.
· The bottom filter cover is
open.
Possible Solution
· Relocate the projector to an area with
proper ventilation.
· Clean the filter.
· Take the projector to your nearest Au-
thorized Sharp Industrial LCD Products
Dealer or Service Center for repair.
· Carefully replace the lamp.
· Take the projector to your nearest Au-
thorized Sharp Industrial LCD Products
Dealer or Service Center for repair.
· Securely install the bottom filter cover.
Maintenance Indicator
TEMPERATURE
WARNING indicator
LAMP REPLACE-
MENT indicator
POWER indicator
As the usage environment can vary significantly, the projector lamp may not operate for 1,500 hours.
ON
•Reset the lamp timer only after replacing the lamp.
Resetting the lamp timer
2
Connect the power
cord.
1
Reset the lamp timer.
Plug the power cord into the AC
socket of the projector.
While pressing ",| and
ENTER on the projector,press
POWER ON on the projector.
“LAMP 0000H ” is displayed,
indicating that the lamp timer is
reset.
LAMP 0000H
Resetting the TOTAL LAMP TIMER