Specifications
SmartPanel Projector Driver Application Note
Sharp XG-MB70X
© 2004 SP Controls Inc. 601 Minnesota Suite 115 San Francisco, CA 94107
help@spcontrols.com
Hidden functions names are based on the Sharp remote and controls on top of the projector. Hidden
functions are accessed by pressing the indicated key while the holding the On key down.
ADJUST controls, ENTER and UNDO navigate through onscreen menus. UNDO is a “return to previous
menu” or “back” command. MENU can also be used as UNDO. The area zoomed with the ENLARGE
function can be moved using the ADJUST keys.
BLACK SCREEN, AV MUTE TOGGLE, and FREEZE are toggling commands.
AUTO SYNC only works when an RGB input is selected.
The hidden functions available for the Sharp with this Driver are as follows:
MENU
ADJUST LEFT
ADJUST RIGHT
ADJUST UP
ADJUST DOWN
ENTER
UNDO
AV MUTE TOGGLE
AUTO SYNC
AUTO FOCUS
AV MUTE ON
AV MUTE OFF
MUTE ON
MUTE OFF
ZOOM UP
ZOOM DOWN
FOCUS UP
FOCUS DOWN
ENLARGE UP
ENLARGE DOWN
PIC MODE
IRIS
KEYSTONE
FREEZE
RESIZE
BLACK SCREEN
D. Relays
The following table specifies the factory preset
settings for the low-current relays found on the rear
of the SmartPanel. The Configuration Utility can
be used to customize these settings your installation.
Relay 1 ON Maintained
Relay 2 ON Momentary
Relay 3 OFF Momentary
Selection Momentary; not Binary
E. Other Presets
The following table specifies other default factory settings for this Driver that affect is control of the
Projector.
Power Status Feedback Method Power Polling (see note 1)
Control Wiring RS-232 and Infrared Emitter
required (see note 2)
Control for the Sharp with this Driver is via RS-232 and Infrared Emitter
The following table specifies settings for the Panel’s configurable timers. For more information on the
inactivity shutdown feature and the lockout timer see the SmartPanel Configuration and Installation
Guide.
Lockout Timer 95 seconds (see note 3)
Inactivity Shutdown Disabled
RELAYS
PWR
ON
MAINT.
PWR
ON
MOM.
PWR
OFF
MOM.
1A
1B
3A
3B
2A
2B
4A
4B
6A
6B
5A
5B
7A
7B
SELECTION
(EXT. SWITCHER CTRL)
4321
500mA MAX. CURRENT