Instruction manual
Table Of Contents
- WARNING
- CAUTION
- --- English version ---
- INTRODUCTION
- IMPORTANT
- PRECAUTION
- CONTENTS
- PARTS AND THEIR FUNCTIONS
- GETTING STARTED
- OVERVIEW OF FLOW OF DAILY SALES ENTRIES
- BASIC SALES ENTRY
- OPTIONAL FEATURES
- CORRECTION
- PRIOR TO PROGRAMMING
- BASIC FUNCTION PROGRAMMING (For Quick Start)
- AUXILIARY FUNCTION PROGRAMMING
- ADVANCED PROGRAMMING
- TRAINING MODE
- READING (X) AND RESETTING (Z) OF SALES TOTALS
- OVERRIDE ENTRIES
- CORRECTION AFTER FINALIZING A TRANSACTION (Void mode)
- OPERATOR MAINTENANCE
- 1 In case of Power Failure
- 2 In Case of Printer Error
- 3 Cautions in Handling the Printer and Recording Paper
- 4 Replacing the Paper Roll
- 5 Removing a Paper Jam
- 6 Cleaning the Print Head
- 7 Removing the Till and the Drawer
- 8 Opening the Drawer by Hand
- 9 Mounting the Spill-proof Cover
- 10 Before Calling for Service
- SPECIFICATIONS
- --- La versión española ---
- INTRODUCCION
- IMPORTANTE
- PRECAUCION
- INDICE
- PARTES Y SUS FUNCIONES
- PARA EMPEZAR
- REGISTRO BASICO DE VENTAS
- CARACTERISTICAS OPCIONALES
- CORRECCION
- PROGRAMACION DE LAS FUNCIONES BASICAS (Para el inicio rápido)
- PROGRAMACION DE FUNCIONES AUXILIARES
- 1 Programación de secciones
- 2 Programación de PLU (codificación de precios) y subsección
- 3 Programación de la tasa de comisión
- 4 Programación de teclas misceláneas
- Tasa para [%1], [%2] y [CONV]
- Importe para [(-)]
- Límite de tasa porcentual para [%1] y [%2]
- Parámetros de función para [%1], [%2] y [(-)]
- Parámetros de función para [CONV]
- Límite de dígitos de entrada para [RA], [RCPT/PO] y [TAX]
- Parámetros de función para [CHK], [CH1], [CH2] y [CA/AT/NS] (cuando se usa como tecla CA)
- 5 Programación de texto
- PROGRAMACION AVANZADA
- 1 Programación de número de caja registradora y de número consecutivo
- 2 Programación 1 de selección de diversas funciones
- 3 Programación 2 de selección de diversas funciones
- Modo de ahorro de energía
- Formato de impresión del mensaje del membrete
- Bloqueo de importe alto (HALO) para metálico en el cajón (CID) (centinela)
- Interfaz RS-232C
- Densidad de la impresora térmica
- Selección del idioma
- Especificación de dependientes de instrucción para el modo de instrucción
- Programación de la tecla AUTO — Tecla de secuencia automática
- 4 Lectura de programas almacenados
- MODO DE INSTRUCCION
- LECTURA (X) Y REPOSICION (Z) DE LOS TOTALES DE VENTAS
- REGISTROS DE ANULACION
- CORRECCION DESPUES DE FINALIZAR UNA TRANSACCION (Modo de cancelación)
- MANTENIMIENTO PARA EL OPERADOR
- 1 En caso de corte de la alimentación
- 2 En el caso de error de impresora
- 3 Precauciones al manejar la impresora
- 4 Reemplazo del rollo de papel
- 5 Extracción del papel atascado
- 6 Limpieza del cabezal de impresión
- 7 Extracción del separador de dinero y del cajón
- 8 Abertura manual del cajón
- 9 Colocación de la cubierta impermeable
- 10 Antes de solicitar el servicio de un técnico

14
Single item entries
Department entries
For a merchandise classification, the cash register provides a maximum of 99 departments. To the
departments, group attributes such as taxable status are applied to items when they are entered.
• When using the department keys (for department 1 to 40)
For department 1 to 20, enter a unit price and press a department key. If you use a programmed unit price,
press a department key only.
For department 21 to 40, enter a unit price, press the
D
key and press a department key. If you use a
programmed unit price, press the
D
key and press a department key.
*
1
Less than the programmed upper limit amounts
When zero is entered, only the sales quantity is
added.
*
2
For the departments 21 through 40, press the
department shift key.
Please note if you press the same key after using the
D
key, it acts as a repeat entry. For
example, when you register an item of dept. 21 using the
D
key and then an item of dept. 1
using the preset unit price, you should use the department code entry key described below for the
dept. 1 item. If you just press the
¡
key to register dept. 1 item, it will act as a repeat entry of
dept. 21 item.
• When using the department code entry key
Enter a department (dept.) code and press the
d
key, then enter a unit price and press the
d
key again. If
the dept. code is programmed to preset price entry style and a unit price is preset, the cash register will finish
its registration operation.
*
1
Less than the programmed upper limit
amounts
When zero is entered, only the sales
quantity is added.
PLU/subdepartment entries
For another merchandise classification, the cash register provides a maximum of 1800 PLUs/subdepartments.
PLUs are used to call up preset prices by a code entry. Subdepartments are used to classify merchandise into
smaller groups under the departments. Every PLU and subdepartment has a code from 1 to 1800, and should
belong to a department to obtain attributes of that department.
The cash register is pre-programmed to PLU mode and zero for unit price. To use PLU entries, their preset unit
prices should be previously programmed. (Refer to page 34.)
To use subdepartment entries, change to subdepartment mode for the PLU codes.
• PLU entries
• Subdepartment (open PLU) entries
* Less than the programmed upper limit
amounts
When zero is entered, only the sales
quantity is added.
PLU code
(1 to 1800)
p
Unit price *
(max. 7 digits)
p
PLU code
(1 to 1800)
p
Dept. code
(1 to 99)
Unit price *
1
(max. 7 digits)
When using a programmed unit price
(In case only preset price entry is allowed.)
dd
Department keyUnit price *
1
(max. 7 digits)
When using a programmed unit price
D
*
2
Item Entries