Specifications
6
ENERGIZER SPECIFICATIONS
Nemtek Energizer Brand Druid Wizord Merlin Merlin Stealth ™ Stealth Master
Model Number 13 LCD 15 LCD 18 LCD 114
LCD
2 4 4 M15S M18S M25S M28S M25M M28M
High Voltage Outputs
Typical energy output into
500 Ohms load (Joules)
3J 4.6J 7.6J 13.8J
(150
)
2J 3.7J 3.7J 4.8J 7.6J 4.8J 7.6J 4.8J 7.6J
Output Voltage into an open circuit 9 000V 9 000V 9 600V 9 000V 7 400V 8 000V 8 000V 8 500V 9 300V 8 500V 9 300V 8 500V 9 300V
High or Low Voltage modes, alarm
monitoring is enabled in both modes
Yes Yes Yes Yes Fixed Fixed Yes Yes Yes Yes Yes Yes Yes
Output voltage settings can be changed
for both the High and the Low voltage
modes
Yes Yes Yes Yes No No Yes Yes Yes Yes Yes Yes Yes
Number of High Voltage monitored zones 1 1 1 1 1 1 1 1 1 2 2 2 2
Number of Earth loop monitored zones 1 1 1 1 1 1 1 1 1 2 2 2 2
Adaptive Power Technology (APT),
reducing false alarms and arcing on the
fence
Yes Yes Yes Yes No No No No No No No No No
Fence Interference detection from foreign
energizers
Yes Yes Yes Yes No Yes Yes No No No No No No
Energizer Controls and Displays
Keypads for the remote control of the
energizer
2 max 2 max 2 max 2 max No No 4 max
1 incl
4 max 4 max 4 max 4 max 4 max 4 max
Tag switch – to control the energizer
without using a keypad
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Remote On/Off input Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes*
Displays the output and return voltages Yes Yes Yes Yes No No No No No No No No No
Display type LCD LCD LCD LCD LED LED LED LED LED LED LED LED LED
Gate and Panic Button inputs
Timed gate switch input, used to monitor
open and closing of the gate
Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes*
Panic button input Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes*
Alarm outputs
Siren output, time programmable Yes Yes Yes Yes Fixed Fixed Yes Yes Yes Yes Yes Yes Yes
Strobe light output to visually indicate an
alarm condition
1 1 1 1 1 1 1 1 1 2 2 2 2
Power supply and battery backup systems
Mains supply voltage*** 230V 230V 230V 230V 230V 230V 230V 230V 230V 230V 230V 230V 230V
Typical power consumption under normal
operating conditions
18VA 18VA 25VA 17VA 17VA 18VA 16VA 27VA 23VA 27VA 25VA 27VA 25VA
Internal battery backup system in case of
power failure, capacity of battery
7 Ah 7 Ah 7 Ah 7 Ah 7 Ah 7 Ah 7 Ah 7 Ah 7 Ah 7 Ah 7 Ah 7 Ah 7 Ah
Typical standby time, with a fully charged
battery
24 hrs 24 hrs 24 hrs 9 hrs 24 hrs 36 hrs 24 hrs 6 hrs 8 hrs 7 hrs 6 hrs 7 hrs 6 hrs
Solar power panels can be connected to
power the energizers, (recommend Watt
size for 24 hr operation)**
60
Watts
60
Watts
140
Watts
140
Watts
- 60
Watts
60
Watts
120
Watts
140
Watts
120
Watts
140
Watts
120
Watts
140
Watts
Solar voltage regulator 5 Amp 5 Amp 10 Amp 10 Amp - 5 Amp 5 Amp 9 Amp 10 Amp 9 Amp 10 Amp 9 Amp 10 Amp
Druid 114 maintains a voltage of 5 600 V into a 100
load at 13.4 J and the voltage is at 7 100 V at a maximum of 13.8 J output into a 150