User`s manual

Chapter 2 Installation
41
and packaging made of antistatic materials or materials that have high resisting,
yet are not insulators.
2.1.3 Site Selection and Requirements
2.1.3.1 Physical Requirements
The MUXpro can be installed in racks, on desktop and shelves. All the connections,
except for the STM-1 interface connection, are made to the rear panel.
For installation in 19” racks, Tainet offers dedicated rack mount kits that enable
installing one or two MUXpro units side-by-side. Two MUXpro units installed with
the rack mount kit occupy a height of 1U.
2.1.3.2 Power Requirements
AC-powered MUXpro units should be installed within 1.5m (5 feet) of an
easily-accessible grounded AC outlet that is capable of furnishing the required AC
supply voltage, in the range of 100 to 240+10 VAC, 50 to 60+3 Hz.
DC-powered MUXpro units require a -36 to -72 VDC power source with positive
terminal grounded. In addition, the DC power connector contains the chassis
(frame) ground terminal.
2.1.3.3 Network and User Connections
This section presents general requirements regarding the connections to the
various MUXpro interfaces. For specific information regarding pin allocations in the
MUXpro connectors, refer to Appendix A .
2.1.3.3.1 Network Connection
Optical Ports. MUXpro units can be ordered with two STM-1optical ports.
Each port has two optical connectors, one is for the receive input and the other is
for the transmit output. The MUXpro can be ordered with FC/PC or SC connectors,
for use over single-mode or multimode fibers.
2.1.3.3.2 E1 Port Connections
Each MUXpro E1 port can be configured to use either one of the following
interfaces