Service manual
UX-A1000U
2 – 13
2 – 13
1 A.M. quiet detect time Binary input 0
2 No. = 16 8 4 2 1 0
3 1 2 3 4 5 1
4 001101
5 0
CPC detection time
4ms 20ms 40ms 70ms 140ms 160ms 200ms 290ms
6 No.6 0 0 0 0 1 1 1 1 1
7 No.7 0 0 1 1 0 0 1 1 1
8 No.8 0 1 0 1 0 1 0 1 1
1 Reserved 0
2 Max OGM record time 15sec 60sec 0
3 Two way record function Disable Enable 0
4 Toll saver Disable Enable 0 OPTION
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Transfer dial recall No Yes 0
1 AGC maximum gain (Line) Binary input 0
2 (10 ~ 25 dB) (1 dB step) No. = 8 4 2 1 1
3 1 2 3 4 0
401011
5 AGC maximum gain (Mic) Binary input 0
6 (10 ~ 25 dB) (1 dB step) No. = 8 4 2 1 1
7 5 6 7 8 1
801100
1
AGC energy refrence level access code (
L
ine)
Binary input 1
2 (-0 ~ -30 dB) (2 dB step) No. = 8 4 2 1 0
3 1 2 3 4 1
410111
5
AGC energy refrence level access code (Mic)
Binary input 1
6 (-0 ~ -30 dB) (2 dB step) No. = 8 4 2 1 1
7 5 6 7 8 0
811011
1 AGC gain adaptation threshold (Line) Binary input 1
2 No. = 8 4 2 1 1
3 1 2 3 4 1
411111
5 AGC gain adaptation threshold (Mic) Binary input 1
6 No. = 8 4 2 1 1
7 5 6 7 8 1
811111
AGC slew rate (Line) Slow Normal Little fast Fast
1 No. 1 0 0 1 1 0
2 No. 2 0 1 0 1 1
AGC slew rate (Mic) Slow Normal Little fast Fast
3 No. 3 0 0 1 1 1
4 No. 4 0 1 0 1 1
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
SW
l
I3
SW
l
I4
SW
l
I5
SW
l
I6
SW
NO.
DATA
NO.
ITEM
Switch setting and function
1
0
Remarks
Initial
setting
SW
l
I7
SW
l
I2