Product specifications

PERIPHERALS
Sharp Electronics Corporation
Procedure
Enter the SRV-Mode as outlined in Section -1
Select [2 SETTING]
Select [01 DEVICE CONFIG]
Select [19 BCR(SCANNER)]
Enter the desired Channel #. The Baud Rate, Data Bits, Parity and Stop Bit should be
set as indicated in the slide.
Depress the [CASH] key when all settings are completed
The menu will return to the Device Config Sub-Menu
Depress the [CANCEL] key to return to the SRV Mode Setting Sub-Menu
NOTE: When “ALL” devices are assigned to the desired Channel No., it is recommended
that a PROGRAM Reset be performed.
Assignment Method: The CHANNEL NO. assignment is required at the machine
where the Scanner is physically connected. For the Inline configuration – there is no
re-routing function available.
Page 93 of 246