Product specifications
FREE KEY LAYOUT
Sharp Electronics Corporation
2. Key Initial
The UP-800 Keyboard layout can be recovered to MRS defaults without risk of losing
previously programmed PLU items, etc by initiating the Initial Key Layout.
Procedure:
① Enter SRV-Mode
② Select [2 SETTING]
③ Select [7 KEY INITIAL]
④ At the “ARE YOU SURE?” prompt, select [1 YES] to restore the MRS1 Defaults or [NO]
to cancel the request
3. PGM Mode Programming – Direct Key
Direct Key programming allows you to link a PLU, DEPT, or Combo Table to a key position
for direct registration.
Procedure:
① Press [MODE]
② Select [6 PGM2 MODE]
③ Select [2 SETTING]
④ Select [2 DIRECT KEY]
⑤ Select a key location where you wish to place a direct Dept., PLU, or Combo key. Use
the up/down arrows to select desired key from the menu or by pressing the key on the
keyboard.
⑥ Using the decimal point key or subtotal key, select the type (PLU, Combo or Dept).
⑦ Enter the PLU code for the respective level(s), or Department code or Combo Table No.
for each Menu Level
UP810F/820F – Key position numbers