Product specifications

EFT&GIFT CARD
Sharp Electronics Corporation
5. PGM2 mode programming:
The PGM2 mode-programming settings outlined in this section are recommended settings
for a typical implementation of the UP-800 EFT function for credit card, debit card and/or
personal checks.
EFT Settings:
Procedure:
Enter the PGM2-Mode by depressing the [MODE] key and selection [6 PGM2 MODE]
Select [15 EFT SETTING]
Select [1 EFT PRESET]
Select [4 PRESET]
Set the following parameters time-out values as shown below followed by depressing the [ENTER]
key
o TIMEOUT1 = 010
o TIMEOUT2 = 180
o TIMEOUT3 = 3000
Set the TEL NO. as instructed for DIAL OUT purposes – using the [TEXT] keyboard
o Example: TEL NO. = 1,2159973963
Set the TEL ID to the designated number provided by Datacap for that merchant file or DIAL OUT
purposes
Set TEL MODE to the desired setting followed by depressing the [ENTER] key
Set FTS MODE = ENABLE for Inline systems or DISABLE for Stand-alone machines
Set the AMOUNT% only when CH. Tips are used
Depress the [ENTER] key to finalize the settings
Depress [CANCEL] when at the EFT SETTING sub-menu to exit to the PGM2 Main-
Menu
NOTE:
The AMOUNT% is used as a calculation basis for DataTran’s Authorization Amount
parameter. It is recommended to set this parameter = 15.00% - 50.00% when using the CH
Tip function
Assignment Method:
When using Nova or any other Host-based service, the Amount% should be preset to
%0. 00
Page 206 of 246