Product specifications
COMMUNICATIONS
Sharp Electronics Corporation
Section-6: MWS Communications Setup
Once the Inline System has been properly established, the communications setup
programming consists of a single PGM2 – mode-programming job, which defines the
parameters which make up the UP-800 MWS IP connection.
1. Related Programming Jobs: MWS System
Procedure – MWS:
Enter PGM2-Mode by pressing the MODE key and selecting 6 PGM2 MODE
① Select [ 19 MWS SETTING]
② Enter the desired parameters – usually prescribed by the application software company:
1. MWS1 IP ADDRESS 1: (000 – 254) Å same as Master’s
2. MWS1 IP ADDRESS 2: (000 – 254) Å same as Master’s
3. MWS1 IP ADDRESS 3: (000 – 254) Å same as Master’s
4. MWS1 IP ADDRESS 4: (000 – 254) Å PC’s unique number (000 – 254)
5. MWS1 Time out: (000 – 999) Å leave at “007”
6. MWS2 IP ADDRESS 1: (000 – 254) Å same as Master’s
7. MWS2 IP ADDRESS 2: (000 – 254) Å same as Master’s
8. MWS2 IP ADDRESS 3: (000 – 254) Å same as Master’s
9. MWS2 IP ADDRESS 4: (000 – 254) Å PC’s unique number (000 – 254)
10. MWS2 Time out: (000 – 999) Å leave at “007”
11. G.W. ADDR 1 – 4: (000 – 255) Å provided by IT assignment
NOTE: The UP-800 MUST be a Master or Std With IRC to communicate through TCP/IP.
Assignment Method:
The MWS SETTING is only available for an Inline system or a unit that has been setup as
STD. WITH IRC (standalone with Inline)
Please consider the general rules listed below when using this feature:
• The MWS IP ADDRESS number must be unique to the Inline system
• The MWS IP ADDRESS represents the IP address of the PC to be connected
Page 179 of 246