Product specifications

INLINE SYSTEM
Sharp Electronics Corporation
Server Sign On/Off Error Processing
There are two methods of error handling for the Server function. When an error occurs
during the Server sign-on a “Lock” error will result. When there is an error upon Server
sign-off process the Manager Function is initiated.
Method-1: Lock Errors (at Sign On)
List of Server Sign On Lock Errors
Error Message Description
NO RECORD The specified Server code is not present in the Master
IRC BUSY The Master is busy – can not respond within the time out period
IRC ERROR Transmission error
Method-2: System Retry (at Sign Off)
If the Master is busy or out of service when a Satellite attempts to send Server data to the
Master, the Satellite display the Manager Retry error message and will wait for input prior to
proceeding.
RETRY? Error:
To “retry” the transmission, select [1 RETRY]
To “terminate” the transmission select [2 ABORT]
This causes the Satellite to place the Server’s data in an error-save file and terminates that
transaction.
Thereafter ordinary sales operations can be performed at the Satellite, as that server will
remain “on” the specific terminal until the Master or communications are recovered.
Assignment Method: Once the Master is recovered, the Server data is updated
automatically.
Please consider the general rules listed below when using this feature:
It is not recommended to perform a PROGRAM RESET at a Satellite when the
Master experiences problems preventing communications
RETRY? Error (Backup Master):
To “retry” the transmission, select [1 RETRY]
To “terminate” the transmission select [2 ABORT]
Page 159 of 246