Product specifications

INLINE SYSTEM
Sharp Electronics Corporation
2 Inline System Setup – with a Backup Master
Please note that the SRV mode IRC SETTING job is combined with SYSTEM PRESET
settings to enable a Backup Master that can provide the functions supported by the Master.
Satellite – Minimum procedure
Procedure:
Enter the SRV-Mode as outlined earlier
Select [2 SETTING]
Select [1 SYSTEM PRESET]
Set SRV#920 = 74x1 followed by [ENTER] key and then [CASH] to return to the SRV
SETTING menu
Depress the [CANCEL] key to return to the SRV Main Menu
Select [3 IRC SETTING]
Select [1 TERMINAL SETTING]
Select [1 SATELLITE]
Enter the desired IP ADDRESS along with choosing the desired parameters:
PLU/UPC Centralized/Individual
PLU/UPC STOCK Centralized/Individual
GLU Centralized/Individual
POSITIVE Centralized/Individual
NEGATIVE Centralized/Individual
Backup Master: Not/Exist
Depress the [CASH] key to complete the IRC SETTING
IMPORTANT:
A PROGRAM RESET should be performed at the completion of the IRC SETTING job
Page 148 of 246