Product specifications
INLINE SYSTEM
Sharp Electronics Corporation
Section-3: Inline System Readings
Inline programming consists of SRV and PGM2 – mode-programming jobs, which define
the system configuration, which makes up the UP-800 Inline system.
1. Entering the SRV-Mode/Program Reset
To enter SRV Mode programming or to perform a program reset, you must toggle the Reset
Switch to the on or forward position and then back to the original off position.
Procedure:
① Unscrew the plate covering the Reset Switch to gain access
② Set the Reset Switch to the “ON” or forward position
③ Set the Reset Switch to the “OFF” or original position.
④ Reattach the plate covering the Reset Switch.
The SRV-mode Main Menu will appear:
IMPORTANT:
A program reset should NOT be performed at any terminal in an Inline configuration when the
system is being used (e.g. Guest Checks are opened or servers are signed on). A safe scenario for
performing a Program Reset is to only perform this when the system is in the CLOSE STORE state
(executed in the PGM2 Mode)
Please consider the general rules listed below when using this feature:
• A Closed Store command can not be executed when Servers remain signed on at the Satellites
Page 124 of 246