Product specifications

PERIPHERALS
Sharp Electronics Corporation
Tare Table Programming
Follow the procedure outlined below to program the tare tables. A maximum of 9 scale tare
tables are available. System Preset 903C = 2 or 3 to allow scale tare tables.
Procedure
Press [MODE]
Select [6 PGM2 MODE]
Select [02 SETTING]
Select [01 ARTICLE]
Select [10 SCALE TABLE]
Select the desired Tare Weight Table
Enter the Tare Weight which is to be deducted when the article is to be weighed
followed by entering the [ENTER] to return to the Scale Table sub-menu.
Assignment Method:
A Tare (Scale Table) weight preset will be based on the setting in SRV Job#903
Please consider the general rules listed below when using this feature:
The Scale Table assignment is by each Department and/or PLU
2. Data Transmission Format
7 bits ASCII code
Even Parity
One Stop bit
Baud Rate: 9600 bps
Page 107 of 246