Product specifications
PERIPHERALS
Sharp Electronics Corporation
Related Programming Jobs: Scale
SRV Mode Related Jobs
SRV Job# Description
Setting – System Preset 902-C = 5
Allows the item subtotal to display on screen.
Otherwise only the weight ad price per pound will
display. Required for scale refund operation
Setting – System Preset 903-B Scale Weight System
Scale is Enabled
Tare Entry is Enabled
Setting – System Preset
903-C
Unit Weight for Scale Entry
Setting – System Preset 906-C Multiplication Entry. If using, UP-P16DP set to 5.
Setting – System Preset 906-D Fractional Qty entries are Enabled
Function No. 35 [SCALE]
Setting – Free Key
950
Function No. 66 [OPEN TARE]
PGM2 Mode
PGM Job # Selection Description Options
01. Department
02. PLU/UPC
01.Article
03. PLU Range
Scale Compulsory / Inhibit/
Enable
2. Setting
10. Scale Table Table 1 – 9 (Weight preset)
Department Programming
Follow the procedure outlined below to assign the Scale status to a department.
Procedure
Enter the PGM2-Mode by turning the MA key counter clock wise to the PGM2 position.
① Press [MODE]
② Select [6 PGM2 MODE]
③ Select [02 SETTING]
④ Select [01 ARTICLE]
⑤ Select [01 DEPARTMENT]
⑥ Select the desired department from the Department list
⑦ Go to the SCALE option and select “INHIBIT”/”ENABLE”/”COMPULSORY” by toggling
the setting with the [.] decimal key or by depressing [SBTL] and making the desired
setting.
Assignment Method:
A Department may be preset as Scale: Inhibited”/”Enabled”/”COMPULSORY”.
Please consider the general rules listed below when using this feature:
• A setting of “COMPULSORY” allows scalable registration without the depression of
the [SCALE] key prior to the entry
• The Fast Food multiplication sequence must be disabled in SRV Job#906-C
Page 105 of 246