Instruction manual

33
As stated earlier (see page 8), there are two systems for collecting clerk sales data: a centralized system
and an individual system.
(1) Centralized clerk file system
In this system, the transaction data on a clerk in each satellite will be transmitted to the master each
time the clerk signs off. You cannot generate an individual clerk report for each satellite. At the master,
you can generate full and individual clerk consolidated reports.
At each satellite, you can generate individual clerk consolidated reports.
If resetting operation for a consolidated individual clerk Z report is made at a satellite where a clerk is
signed on, the data on transactions being handled by the clerk or cashier is also added and printed
out.
If a consolidated full clerk Z report is taken at the master while a clerk signs on at a satellite, that
clerk’s sales data are excluded from the report and resetting operation for the clerk can not be made.
Full clerk report sample in the centralized clerk file system (master)
For detailed information on report items, see the UP-800F/UP-810F Instruction Manual.
NOTE
000123 #0107 22/07/2008 19:03 [0001]
CLERK
0001
Z1
CLERK STOP
ALL CLERK
CLK#
0001
CLERK0001
ORDER TL 115.25
CLK#
0002
CLERK0002
ORDER TL 63.75
CLERK START
Machine no.
Consecutive no.
Date
Report type
Clerk code
Clerk name
Data on clerk #0001
Report mode
Data on clerk #0002
(If the report is taken with clerk #0002 signed on at a
satellite, the data on the clerk is not printed.)
Reset counter
Time
5. Clerk report