Empty the ash container
EntaschungWärmetauscher
EntaschungRetorte
Chamber ash removal:
Unscrew the wing nuts on the ash container flange
Separate the ash container from the flange and take the ash container to the ash
disposal point
Heat exchanger ash removal
Unscrew the wing nuts on the ash box flange
Separate the ash box from the flange and take the ash box to the ash disposal
point
Boiler with ash drawer (depending on model):
Remove the star-shaped screws on the ash drawer flange
Pull out the ash drawer and take it to the ash disposal point
Servicing
4
Maintenance schedule