Operating instructions
WARNING
Inspection and cleaning of the combustion chamber with the combustion chamber
temperature sensor in position
Risk of damage to the thermocouple!
Before inspection and cleaning work in the combustion chamber:
❒ Mark the position of the thermocouple.
❒ Loosen the clamp and pull out the thermocouple.
➥ After maintenance:
❒ Carefully clean any tar or soot deposits from the thermocouple.
❒ Re-insert the thermocouple to the marked position and fix in place with the
clamp.
NOTICE
We recommend that you keep a maintenance book in accordance with ÖNORM
M7510 of the Technical Directive for Fire Prevention (TRVB)
4.2 Inspection and cleaning
For inspection and cleaning use the cleaning kit provided. The cleaning kit consists of:
▪
Chamber plate (triangular plate)
▪ Flat scraper
▪ Large brush (Ø 81 mm)
▪ Small brush (Ø 53 mm)
❒ We recommend that you also use an industrial vacuum cleaner.
4
Servicing
Inspection and cleaning
28 Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com