Installation Instructions

E 4
C
L
Top view
A
Anti-Tip block
Mounting cleat
B
C
Drawer face
Trim
face
Note: the mounting surface
of the finished cleat must sit
1-17/32”
(38.9 mm) back from
the face of the cabinet.
**
MICROWAVE DRAWER FLUSH MOUNT, MEASUREMENTS AND INSTALLATION INSTRUCTIONS
Figure 2
1. Prepare cabinet opening as shown in Figure 2.
C
L
H
E
F
D
N
N
A
B
J
I
M
K
G
I
I
A. 6" (152.4 mm)
B. Suggested electrical outlet
location*
C. Anti-Tip block
D. 5" (127.0 mm)
E. 3-1/2" (88.9 mm)
F. 4" (101.6 mm)
G. 30-5/16" (769.9 mm) min
30-5/8" (777.9 mm) max
H. 14-13/16" (376.2 mm) to bottom
of Anti-Tip block
I. 1-17/32" (38.9 mm) Refer to
Figure 3 **
J. 23-1/2" (596.9 mm) minimum
depth
K. 22-1/8" (562.0 mm)
L. Floor must support 100 lb (45.4
kg)
M. 16-1/4" (412.8 mm) opening
* See Figure 4C for detail
N. Allow 4-1/8" (104.4 mm)
D
G
A
B
C
J
H
I
F
E
Figures 1 and 2 contain many Microwave Drawer measurements
for reference when planning the drawer’s location.
This Microwave Drawer can be installed below any electric or
gas wall oven.
* Can also be installed using an electrical outlet in an adjacent cabinet
within the area where the provided electrical cord can reach. Power
cord access hole in cabinet should be a minimum 1-1/2" diameter
hole and deburred of all sharp edges.
IMP O R TANT
Always allow sufcient power cord length to the
electrical outlet to prevent tension.
Always check electrical codes for requirements
A. 21-5/8" (549.3 mm)
B. 4-11/16" (119.1 mm)
C. 1-3/4" (44.5 mm)
D. 21-7/8" (555.6 mm)
E. 23-5/8" (600.1 mm)
F. 16" (406.4 mm)
G. 14-19/32" (370.7 mm)
H. 1-17/32" (38.9 mm) door thickness
I. 15" (381.0 mm) auto drawer opening
J. 4" (101.0 mm)
Figure 1
Figure 3
A. 22-1/8" (596.9 mm) mounting cleat opening width
B. 0"ush
C. 1-17/32" (38.9 mm) front of cleat to cabinet face
Note: For pre-existing 30” cabinet openings that desire a standard
mount,llerpanelswillneedtobeinstalledoneithersideofthecut
out to properly mount the extension kit panels.