SJ-48H-S SJ-51H-S SJ-55H-S SERVICE MANUAL S0653SE55BPWI REFRIGERATOR-FREEZER MODELS SJ-48H-S SJ-51H-S SJ-55H-S In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used. This equipment complies with the requirements of Directives 89/336/EEC and 73/23/EEC as amended by 93/68/EEC. DESTINATION .........................
SJ-48H-S SJ-51H-S SJ-55H-S ENERGY LABEL Usage of "the ENERGY LABEL" When displaying this refrigerator in the shop-window, attach the "ENERGY LABEL" to it in the following procedure.
SJ-48H-S SJ-51H-S SJ-55H-S SPECIFICATIONS Items Type Outer dimensions (Including spacer) Height Width Depth Rated storage volume Rated gross volume Defrosting Temperature control No-frost freezer Interior lamp Caster Evaporating pan Refrigerator Compartment Freezer Compartment System Start Finish Refrigerator shelf S Refrigerator shelf L Glass shelf Fruit and Vegetable case Egg pocket Egg holder Bottle pocket Free pocket Chilled case Freezer shelf L Freezer shelf S Ice cube maker Ice cube box SJ-4
SJ-48H-S SJ-51H-S SJ-55H-S THE FICHE (according to ANNEX NO.
SJ-48H-S SJ-51H-S SJ-55H-S DESIGNATION OF VARIOUS PARTS The names in parenthesis are the denominations used in the REPLACEMENT PARTS LIST. 1 2 3 4 19 5 20 17 18 6 21 22 7 8 9 10 11 12 13 14 23 24 15 20 16 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. Freezer shelf (LARGE) (Freezer tray L) Freezer temp. control knob Freezer shelf (SMALL) (Freezer tray S) Ice cube maker Ice cube box (Ice storage box) Chilled case Light (Lamp) Refrigerator temp.
SJ-48H-S SJ-51H-S SJ-55H-S LIST OF ELECTRICAL PARTS ITEMS F-Thermostat Defrost thermo. Thermo. fuse Fan motor Defrost heater Door switch Damper thermostat Defrost timer TYPE NAME MM1-8025 US-602S MGT4A50072 3R00044B MM6-4015 MM1-7B01 MM1-6129 TMDF904FD2 RATING 250V 3A 250V 8A 250V 10A 220 - 240V 50Hz at 230V 150W(220-240V) 250V 0.
SJ-48H-S SJ-51H-S SJ-55H-S WIRING DIAGRAM Be sure to replace the electrical parts with specified ones for maintaining the safety and performance of the set. G Br O Y R P B Bk S-B G-Y W : GRAY : BROWN (live) : ORANGE : YELLOW : RED : PINK : BLUE (neutral) : BLACK : SKY-BLUE : GREEN-YELLOW (earth) : WHITE CONNECTED IN TERMINAL BOX CONNECTOR TIMER THERMOSTAT (Br) TM (R) (G) INTERIOR LIGHT (Bk) FAN MOTOR FM L 3PIN PLUG/ CORD (S-B) THERMO.
SJ-48H-S SJ-51H-S SJ-55H-S Fan motor Defrost thermo. FM F-thermostat FREEZER (E.V cov. ass'y) Thermo. fuse Defrost heater C1(LR-09-1V) (O) 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 1 (W) 2 (G) (P) (B) (Br) (R) (Bk) (W) (Y) C2(ELR-02V) Door switch 3(Push close) 1 4(Push open) 3 1 4 (C-part.
SJ-48H-S SJ-51H-S SJ-55H-S FUNCTIONS 1. ADJUSTABLE TEMPERATURE CONTROL (1) Temperature control of freezer Thermostat (senses freezer temperature) operates on ON/OFF switchover to control the compressor and allows the freezer temperature to keep at a suitable temperature. However adjust the freezer temp. control knob as follows depending upon the storing condition of foods. 3 MED 4 5 2 7 MAX Coldest 1 MIN PURPOSE KNOB SETTING 6 MAX(Coldest) For making ice rapidly or fast freezing.
SJ-48H-S SJ-51H-S SJ-55H-S 2. DEFROSTING (1) No defrosting operation is necessary No defrosting operation is necessary. As this machine is so designed that a built-in evaporator cools air and a fan circulates cooled air, neither the freezer nor the refrigerator is frosted, though the evaporator is frosted. The frosted evaporator is defrosted automatically due to the function of defrosting timer and heater, requiring no defrosting operation. (2) Where is melted ice brought 1.
SJ-48H-S SJ-51H-S SJ-55H-S (4) As a reference to determine the causes of trouble, malfunction and phenomena are described below. Refer to the following when repairing. 1. Disconnection of defrost heater As off-cycle defrosting is performed, the defrosting time is extremely prolonged. Each time defrosting is started, the freezer temperature rises and a portion of ice and stored foods are melted. 2. Melted thermo. fuse or opened-circuit due to the defect of defrost thermostat.
SJ-48H-S SJ-51H-S SJ-55H-S MODIFICATION PROCEDURE OF THE DOOR OPEN SIDE It is possible to change the door to left side opening. To modify the door to left side opening, REFRIGERATOR HINGE KITS (for left side opening) SJ-L815HD (optional item )is necessary. SJ-L815HD OPERATION MANUAL REFRIGERATOR HINGE KITS (for left side opening) Model SJ-L815HD These kits are used to change the refrigerator doors from right to left opening.
7 15 C 5 E B D 8 8 5 F 13 6 5 6 5 10 1 18 17 A 9 10 1 11 18 3 4 2 9 1 G 16 H 2.5±1.0mm 11.3mm 1.0±1.
SJ-48H-S SJ-51H-S SJ-55H-S ASSEMBLING PROCEDURES OF MAIN PARTS AND CAUTIONS CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY REPAIRING. 1. R-CONTROL COV. ASSEMBLY A-sealer air guid. B Defrost timer D timer lead ass'y A-sealer air guid. D Lamp socket R-air guider B R-air guider A A-sealer RC-box Damper thermostat A-sealer RC-duct RA-insulation Lamp C-box base Thermo. cap sealer Warning label Dial sealer A-sealer thermo. cap A-sealer air guid. C A-sealer air guid. D R-temp.
SJ-48H-S SJ-51H-S SJ-55H-S C-box base Start A sealer air guid. C Overlap B datum A-sealer RC-duct A-sealer RC-box B A-sealer RC-duct A-sealer RC-box datum Start C-box base Overlap (The back of C-box base) SEC. BB 5±1 mm 3±1 mm Damper thermostat Less than 130 mm (2) Forming sensor of Damper thermostat Stick thermo. cap. sealer 25±2 mm Less than 12 mm NOTE Minimum bending radius is R5. There should be no gas leak by reforming of sensor tube.
SJ-48H-S SJ-51H-S SJ-55H-S (4) Fixing of Lamp socket, Defrost timer SKY-BLUE Insert Pin No.6 D timer lead ass'y Connect Defrost timer R-Cbox cover 6 7 BROWN Insert Pin No.7 Lamp socket Screw Lamp (5) Fixing of R-Cbox cover Claws(2 places) Set R-temp. control knob R-Cboxcover Claws(2 places) 2±1 mm Stick Lamp label LAMP RATING 240V.
SJ-48H-S SJ-51H-S SJ-55H-S 2. E.V COVER ASSEMBLY F-thermostat Lead E.V cover ass'y. E.V cover sealer E L-band C E.V cover sealer B E.V cover E.V cover sealer C Fan clamp Propeller fan L-band C Fan motor cushion A Defrost thermo. ass'y Fuse ass'y Motor cushion Alminum tape Fan motor Fan motor cushion B E.V cover sealer A (1) Sticking of sealer to E.V cover E.V cover sealer A Overlap 10mm(min.) E.V cover sealer B E.V cover [View from A direction] [Front View] E.V cover sealer E E.
SJ-48H-S SJ-51H-S SJ-55H-S (2) Fixing of Fan motor and Fan Motor cushion Motor cushion Fan motor cushion B Fan motor cushion A Fan motor cushion B Fan motor cushion A D C 2 mm C D Motor cushion -2 Motor cushion Sec CC See DD Motor cushion Motor cushion Fan motor cushion B Fan motor cushion A Fan motor Check claw is surely fixed to the hole of Fan motor cushion. Set Fan clamp to Propeller fan and insert it to the shaft of Fan motor. Propeller fan E .
SJ-48H-S SJ-51H-S SJ-55H-S (3) Wiring of Lead Wire B B L-band C Defrost thermo. ass'y C Alminum tape L-band C Fuse ass'y A B Detail A Detail C Detail Bend this pin Fasten Defrost thermo. ass'y's wires as bellow. And set it inside of the four pins. 7mm Lead wire “WHITE” Cut off to 7mm or shorter Fuse ass'y Alminum tape Horizontally Thermo. sensing element side (Silver metal) (4) Setting of Lead E.V cover ass'y and F-thermostat E.V cover Lead E.
SJ-48H-S SJ-51H-S SJ-55H-S COOLING UNIT SJ-48H Mark: Refrigerant flow Mark: Brazing portion Hot pipe L (Side condenser) Hot pipe (DP-condenser) Hot pipe R (Side condenser) Evaporator Suction pipe Sub. condenser Compressor Capillary tube Dryer Figure C-1. Cooling unit Dryer Capillary tube Charge pipe L Hot pipe Sub. condenser Evaporator Charge pipe L Compressor Suction pipe S.P. connector Sub. condenser Figure C-2.
SJ-48H-S SJ-51H-S SJ-55H-S SJ-51H, SJ-55H Mark: Refrigerant flow Mark: Brazing portion Hot pipe L (Side condenser) Hot pipe (DP-condenser) Hot pipe R (Side condenser) Back condenser Evaporator Suction pipe Sub. condenser Compressor Connector pipe Capillary tube Dryer Figure C-3. Cooling unit Dryer Capillary tube Charge pipe L Hot pipe Sub. condenser Evaporator Charge pipe L Connector pipe Compressor Suction pipe S.P. connector Sub. condenser Figure C-4.
SJ-48H-S SJ-51H-S SJ-55H-S REPLACEMENT PARTS LIST REF. NO. PART NO.
SJ-48H-S SJ-51H-S SJ-55H-S REF. NO. PART NO. DESCRIPTION 2-67 2-70 2-71 2-72 2-73 2-74 2-75 2-76 2-78 2-79 2-80 2-81 2-82 2-83 2-84 2-86 LPLTMA403CBP0 PSEL-B167CBE0 PSEL-A552CBE0 PSEL-B120CBE0 PSEL-B121CBE0 PSEL-B122CBE0 PSEL-B124CBE0 LHLD-A124CBFB LPLTMA399CBP0 LBND-A019CBE0 PBOX-A071CBFA PPIPPA069CBE0 PTUBBA058CBE0 PSEL-B242CBE0 PSEL-B243CBE0 LBND-A026CBE0 Drain Support AL E.V Cover Sealer E Dial Sealer A-Sealer RC-Box A-Sealer RC-Duct A-Sealer Thermo.Cap. A-Sealer Air Guid.
SJ-48H-S SJ-51H-S SJ-55H-S REF. NO. 5-20 5-21 5-24 5-25 5-26 PART NO. DESCRIPTION UTNA-A230CBFA UTNA-A229CBFA FSRA-A160CBK0 FSRA-A161CBK0 PCAP-A053CBEE Free Set Shelf F Free Set Shelf B Ref.Tray L Ass’y Ref.Tray Ass’y Venti.
SJ-48H-S SJ-51H-S SJ-55H-S 2 1 4 3 6 5 DOOR PARTS 3-9 A A 3-6 3-10 3-5-2 3-5 3-14 B B 3-10 3-25 C C 5-3 3-15-4 3-12 3-20 5-5 3-5-3 3-5-1 3-15-3 D D 5-2 3-15 3-16 E E 5-4 F F 5-1 G G 3-17 3-20 3-15-2 H SJ-48H-S SJ-51H-S SJ-55H-S 3-15-1 1 2 4 3 25 5 6 H
SJ-48H-S SJ-51H-S SJ-55H-S 2 1 4 3 6 5 CABINET PARTS 2-65 A 2-16 2-28 2-21 A 2-64 1-6 2-20 2-17 2-70 4-1 1-5 2-4 2-60 2-63 1-20 2-19 1-17 2-2 2-29 4-1 B B 2-13 2-22 2-62 1-1 2-23 2-81 5-7 5-6 2-66 C 2-36 C 1-21 5-17 2-76 5-11 2-33 2-79 2-37 5-18 4-9 2-67 5-9 1-10 4-14 2-24 2-78 6-18 4-3 6-5 D D 2-15 5-26 2-82 2-49 2-34 2-80 5-13 2-75 2-79 1-9 2-11 5-19 1-22 2-72 E 2-40 1-7 1-3 2-8 2-84 E 1-19 2-14 2-8-2 2-73 2-38 1-8 2-61 2-7-1 2-39 2-
SJ-48H-S SJ-51H-S SJ-55H-S PLUG TYPE Type Section of Power Supply Cord Plug BF Destination I (Only for U.K.
SJ-48H-S SJ-51H-S SJ-55H-S 28 '96 SHARP CORP. (0U0.