Service manual
AL-2040CS CONSUMABLE PARTS 3 - 1
[3] CONSUMABLE PARTS
1. Supply system table
Common to all destinations
2. Environmental
The environmental conditions for assuring the copy quality and the machine operations are as follows:
(1) Normal operating condition
Temperature: 20 - 25°C
Humidity: 65 ± 5%RH
(2) Acceptable operating condition
(3) Transport condition
(4) Supply storage condition
No. Name Content Life Product name Package
1 Develop cartridge (Black) x 1 Toner/developer cartridge x 1
(Toner: Net weight 213g) (Developer: Net weight 190g)
6K
(5% document)
AL-100TD 5
2 Develop cartridge (Black) x 1 Toner/developer cartridge x 1
(Toner: Net weight 124g) (Developer: Net weight 190g)
4K
(5% document)
AL-110TD 5
3 Drum cartridge Drum cartridge 18K AL-100DR 5
Humidity (RH)
85%
60%
20%
10˚C 30˚C 35˚C
Humidity (RH)
90%
60%
15%
–25˚C 30˚C 40˚C
Humidity (RH)
90%
20%
–5˚C 45˚C